EC000019 version 9

Coaxial cable

Published in
ETIM-10.0
Also called
Antenna cable, Audio cable, Backbone cable, Bamboo cable, Cable, CATV cable, CCTV cable, Data network cable, Ethernet cable, Multi coax, Network cable, RG 11, RG 174, RG 213, RG 214, RG 223, RG 58, RG 59, RG 6, RG 62, RG 71, RG 8, Signal cable, Telematics cable, Trunk cable, Twinax, Twinax cable, Video cable

Options (3)

#FeatureTypeUnitAllowed values
1
Paired co-axial cable
L——
2
2 core co-axial cable (twinax)
L——
34
Circuit integrity according to IEC 60331-23
L——

Measurements (7)

#FeatureTypeUnitAllowed values
3
Diameter inner conductor
Nmm—
7
Diameter outer conductor
Nmm—
36
Outer diameter approximate
Nmm—
37
Min. permitted bending radius, moving application with forced guidance
Nmm—
38
Min. permitted bending radius, moving application/free movement
Nmm—
39
Min. permitted bending radius, stationary application/permanent installation
Nmm—
45
Weight
Nkg/km—

Material (11)

#FeatureTypeUnitAllowed values
4
Inner conductor material
A—
5
Inner conductor surface
A—
8
Outer conductor material
A—
9
Outer conductor surface
A—
14
Material armouring
A—
16
Material outer sheath
A—
17
Specification material outer sheath
A—
26
Low smoke according to EN IEC 61034-2
L——
27
Halogen free according to EN IEC 60754-1
L——
28
Halogen free according to EN IEC 60754-2
L——
29
Halogen free according to EN IEC 60754-3
L——

Model/type (4)

#FeatureTypeUnitAllowed values
10
Type of outer conductor
A—
12
Number of screen layers
N——
15
With rodent protection
L——
19
Number of sheath layers
N——

Colour (1)

Protection (10)

#FeatureTypeUnitAllowed values
20
Flame retardant according to IEC 60332-1-2
L——
21
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
L——
22
Flame retardant according to IEC 60332-3-22 (Cat A)
L——
23
Flame retardant according to IEC 60332-3-23 (Cat B)
L——
24
Flame retardant according to IEC 60332-3-24 (Cat C)
L——
25
Flame retardant according to IEC 60332-3-25 (Cat D)
L——
30
Reaction-to-fire according to EN 13501-6: Class
A—
31
Reaction-to-fire according to EN 13501-6: Smoke production
A—
32
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
A—
33
Reaction-to-fire according to EN 13501-6: Acidity
A—

Electrical (1)

#FeatureTypeUnitAllowed values
35
Characteristic impedance
NOhm—

Mounting/installation (3)

#FeatureTypeUnitAllowed values
40
Max. tensile strength during installation
NkN—
41
Suitable for underground installation
L——
42
Approved type of underground installation
A—

Operating conditions (2)

#FeatureTypeUnitAllowed values
43
Permitted cable outer temperature during assembling/handling
R°C—
44
Permitted cable outer temperature after assembling without vibration
R°C—