EC000837 version 9
Power cable >= 1 kV, for moving application
- Published in
- ETIM-10.0, ETIM-9.0
- Also called
- Cable, Energy cable, Energy cable >= 1 kV, for moving application, High voltage power cable, Trailing cable
Material (10)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 1 | Conductor material | A | — | |
| 2 | Conductor surface | A | — | |
| 17 | Material core insulation | A | — | |
| 26 | Material armouring | A | — | |
| 30 | Material outer sheath | A | — | |
| 31 | Specification material outer sheath | A | — | |
| 40 | Low smoke according to EN IEC 61034-2 | L | — | — |
| 41 | Halogen free according to EN IEC 60754-1 | L | — | — |
| 42 | Halogen free according to EN IEC 60754-2 | L | — | — |
| 43 | Halogen free according to EN IEC 60754-3 | L | — | — |
Connection (4)
Measurements (8)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 4 | AWG size | A | — | |
| 49 | Cable width approximate | N | mm | — |
| 50 | Cable height approximate | N | mm | — |
| 51 | Outer diameter approximate | N | mm | — |
| 52 | Min. permitted bending radius, moving application with forced guidance | N | mm | — |
| 53 | Min. permitted bending radius, moving application/free movement | N | mm | — |
| 54 | Min. permitted bending radius, stationary application/permanent installation | N | mm | — |
| 60 | Weight | N | kg/km | — |
Other (7)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 6 | Conductor category | A | — | |
| 11 | Stranding element | A | — | |
| 12 | Screen over stranding element | A | — | |
| 13 | Screen over stranding | A | — | |
| 18 | Specification core insulation | A | — | |
| 20 | Core identification | A | — | |
| 25 | Armouring/reinforcement | A | — |
Electrical (3)
Model/type (6)
Options (4)
Operating conditions (3)
Protection (12)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 24 | Protective barrier | A | — | |
| 34 | Flame retardant according to IEC 60332-1-2 | L | — | — |
| 35 | Flame retardant according to IEC 60332-3-21 (Cat A F/R) | L | — | — |
| 36 | Flame retardant according to IEC 60332-3-22 (Cat A) | L | — | — |
| 37 | Flame retardant according to IEC 60332-3-23 (Cat B) | L | — | — |
| 38 | Flame retardant according to IEC 60332-3-24 (Cat C) | L | — | — |
| 39 | Flame retardant according to IEC 60332-3-25 (Cat D) | L | — | — |
| 44 | Reaction-to-fire according to EN 13501-6: Class | A | — | |
| 45 | Reaction-to-fire according to EN 13501-6: Smoke production | A | — | |
| 46 | Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | A | — | |
| 47 | Reaction-to-fire according to EN 13501-6: Acidity | A | — | |
| 48 | Oil resistant according to EN IEC 60811-404 | L | — | — |