EC001037 versión 10
Motor starter/motor starter combination
- Publicada en
- ETIM-10.0
- También se llama
- Contactor automatic, Direct online starter (DOL), Direct starter, Motor protection switch, Motor protective circuit-breaker, Motor starter, Motor starter combination, Repair switch, Reversing starter, Star-delta starter, Starter
Model/type (6)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 1 | Type of motor starter | A | — | |
| 2 | With short-circuit release | L | — | — |
| 27 | With transformer | L | — | — |
| 28 | Number of command positions | N | — | — |
| 31 | Number of indicator lights | N | — | — |
| 33 | With fuse | L | — | — |
Electrical (16)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 3 | Rated control supply voltage AC 50 Hz | R | V | — |
| 4 | Rated control supply voltage AC 60 Hz | R | V | — |
| 5 | Rated control supply voltage DC | R | V | — |
| 6 | Voltage type for actuating | A | — | |
| 7 | Rated operation power at AC-3, 230 V, 3-phase | N | kW | — |
| 8 | Rated operation power at AC-3, 400 V | N | kW | — |
| 9 | Rated power, 460 V, 60 Hz, 3-phase | N | kW | — |
| 10 | Rated power, 575 V, 60 Hz, 3-phase | N | kW | — |
| 11 | Rated operation current Ie | N | A | — |
| 12 | Rated operation current at AC-3, 400 V | N | A | — |
| 13 | Overload release current setting | R | A | — |
| 14 | Rated conditional short-circuit current, type 1, 480 Y/277 V | N | A | — |
| 15 | Rated conditional short-circuit current, type 1, 600 Y/347 V | N | A | — |
| 16 | Rated conditional short-circuit current, type 2, 230 V | N | A | — |
| 17 | Rated conditional short-circuit current, type 2, 400 V | N | A | — |
| 18 | Power consumption | N | W | — |
Connection (4)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 19 | Number of auxiliary contacts as normally open contact | N | — | — |
| 20 | Number of auxiliary contacts as normally closed contact | N | — | — |
| 24 | Type of electrical connection of main circuit | A | — | |
| 25 | Type of electrical connection for auxiliary- and control current circuit | A | — |
Operating conditions (1)
Options (2)
Other (1)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 23 | Release class | A | — |
Mounting/installation (1)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 26 | Suitable for rail mounting | L | — | — |
Application (1)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 29 | Suitable for emergency stop | L | — | — |
Approval/certification (1)
Protection (2)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 34 | Degree of protection (IP) | A | — | |
| 35 | Degree of protection (NEMA) | A | — |
Communication (21)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 36 | Supporting protocol for TCP/IP | L | — | — |
| 37 | Supporting protocol for PROFIBUS | L | — | — |
| 38 | Supporting protocol for CAN | L | — | — |
| 39 | Supporting protocol for INTERBUS | L | — | — |
| 40 | Supporting protocol for ASI | L | — | — |
| 41 | Supporting protocol for Modbus | L | — | — |
| 42 | Supporting protocol for Data-Highway | L | — | — |
| 43 | Supporting protocol for DeviceNet | L | — | — |
| 44 | Supporting protocol for SUCONET | L | — | — |
| 45 | Supporting protocol for LON | L | — | — |
| 46 | Supporting protocol for PROFINET IO | L | — | — |
| 47 | Supporting protocol for PROFINET CBA | L | — | — |
| 48 | Supporting protocol for SERCOS | L | — | — |
| 49 | Supporting protocol for Foundation Fieldbus | L | — | — |
| 50 | Supporting protocol for EtherNet/IP | L | — | — |
| 51 | Supporting protocol for AS-Interface Safety at Work | L | — | — |
| 52 | Supporting protocol for DeviceNet Safety | L | — | — |
| 53 | Supporting protocol for INTERBUS-Safety | L | — | — |
| 54 | Supporting protocol for PROFIsafe | L | — | — |
| 55 | Supporting protocol for SafetyBUS p | L | — | — |
| 56 | Supporting protocol for other bus systems | L | — | — |