EC001449 version 9
Device for monitoring of safety-related circuits
- Group
- Relays EG000019
- Published in
- ETIM-10.0, ETIM-9.0
- Also called
- Basic device, Expansion device, Relay
Differences between version 9 and the previous one, based on the change codes ETIM publishes. The class is listed as Changed: 14 new features, 32 changed, 4 removed and 15 changes in allowed values.
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 2 | EF003972Changed Suitable for rail mounting | L | — | — |
| 3 | EF003340Changed With detachable clamps | L | — | — |
| 4 | EF003961Changed Type of electric connection | A | — | |
| 5 | EF002991New Voltage type (supply voltage) | A | — | |
| 6 | EF007532New Supply voltage AC 50 Hz | R | V | — |
| 7 | EF007533New Supply voltage AC 60 Hz | R | V | — |
| 8 | EF007534New Supply voltage DC | R | V | — |
| 9 | EF007270Changed Suitable for monitoring of position switches | L | — | — |
| 10 | EF007268Changed Suitable for monitoring of emergency-stop circuits | L | — | — |
| 11 | EF007272Changed Suitable for monitoring of valves | L | — | — |
| 12 | EF007269Changed Suitable for monitoring of optoelectronic protection equipment | L | — | — |
| 13 | EF007271Changed Suitable for monitoring of tactile sensors | L | — | — |
| 14 | EF007266Changed Suitable for monitoring of magnetic switches | L | — | — |
| 15 | EF007267Changed Suitable for monitoring of proximity switches | L | — | — |
| 17 | EF000346New Power consumption | N | W | — |
| 18 | EF003342Changed With start input | L | — | — |
| 19 | EF004057Changed With muting function | L | — | — |
| 20 | EF003343Changed With feedback circuit | L | — | — |
| 21 | EF001129Changed Release-delay | R | s | — |
| 22 | EF002954New Type of control voltage 1 | A | — | |
| 23 | EF002952New Control voltage 1 | R | V | — |
| 24 | EF002955New Type of control voltage 2 | A | — | |
| 25 | EF002953New Control voltage 2 | R | V | — |
| 26 | EF003344Changed Number of outputs, safety related, undelayed, with contact | N | — | — |
| 27 | EF003345Changed Number of outputs, safety related, delayed, with contact | N | — | — |
| 28 | EF003346Changed Number of outputs, safety related, undelayed, semiconductors | N | — | — |
| 29 | EF003347Changed Number of outputs, safety related, delayed, semiconductors | N | — | — |
| 30 | EF003348Changed Number of outputs, signalling function, undelayed, with contact | N | — | — |
| 31 | EF003349Changed Number of outputs, signalling function, delayed, with contact | N | — | — |
| 32 | EF003350Changed Number of outputs, signalling function, undelayed, semiconductors | N | — | — |
| 33 | EF003351Changed Number of outputs, signalling function, delayed, semiconductors | N | — | — |
| 34 | EF005294New Voltage type (operating voltage) | A | — | |
| 35 | EF008206New Operating voltage AC 50 Hz | R | V | — |
| 36 | EF008207New Operating voltage AC 60 Hz | R | V | — |
| 37 | EF008208New Operating voltage DC | R | V | — |
| 38 | EF006706New Rated switch current | N | A | — |
| 39 | EF004105Changed Type of safety according to IEC 61496-1 | A | — | |
| 40 | EF007498Changed Stop category according to IEC 60204 | A | — | |
| 41 | EF007399Changed Performance level according to EN ISO 13849-1 | A | — | |
| 42 | EF009889Changed SIL according to IEC 61508 | A | — | |
| 43 | EF004145Changed With approval for BG BIA | L | — | — |
| 44 | EF001783Changed With approval according to UL | L | — | — |
| 45 | EF000008Changed Width | N | mm | — |
| 46 | EF000040Changed Height | N | mm | — |
| 47 | EF000049Changed Depth | N | mm | — |
| 48 | With approval for TÜV | L | — | — |
| 11 | EF003978Deleted Rated control supply voltage AC 50 Hz | R | V | — |
| 12 | EF003979Deleted Rated control supply voltage AC 60 Hz | R | V | — |
| 13 | EF003980Deleted Rated control supply voltage DC | R | V | — |
| 14 | EF008242Deleted Voltage type for actuating | A | — |