EC001821 version 7

Diffuse reflective photoelectric sensor

Published in
ETIM-10.0
Also called
Light curtain, Light scanner, energetic, Light sensor, Push button

Performance (3)

#FeatureTypeUnitAllowed values
1
Operating distance
Rmm—
46
Response time
Nms—
47
Transmission range of the safety field
Nm—

Options (1)

#FeatureTypeUnitAllowed values
2
Pre failure notice
L——

Model/type (10)

#FeatureTypeUnitAllowed values
3
With time function
L——
6
With reflector
L——
11
With other analogue output
L——
31
Type of switching output
A—
32
Type of switch function
A—
36
Construction type housing
A—
49
Type of safety according to IEC 61496-1
A—
52
With monitoring function downstream switching devices
L——
55
Type of light
A—
59
With restart blockage
L——

Other (7)

#FeatureTypeUnitAllowed values
4
Max. switching distance
Nmm—
12
Setting procedure
A—
41
Sensing mode
A—
45
Min. reflector distance
Nmm—
48
Switching frequency
NHz—
54
Wavelength of the sensor
Nnm—
56
Light dot
Nmm²—

Electrical (7)

#FeatureTypeUnitAllowed values
5
Max. output current
NmA—
44
Max. output current at protected output
NmA—
50
Switching voltage of OSSD at state "high"
NV—
51
Voltage type
A—
64
Rated control supply voltage AC 50 Hz
RV—
65
Rated control supply voltage AC 60 Hz
RV—
66
Rated control supply voltage DC
RV—

Connection (10)

#FeatureTypeUnitAllowed values
7
Analogue output 0 V ... 10 V
L——
8
Analogue output 0 mA ... 20 mA
L——
9
Analogue output 4 mA ... 20 mA
L——
10
Analogue output -10 V ... +10 V
L——
25
Number of semiconductor outputs with signalling function
N——
26
Number of contact energized outputs with signalling function
N——
27
Number of protected semiconductor outputs
N——
28
Number of protected contact energized outputs
N——
30
Type of electric connection
A—
57
AWG-number
N——

Communication (13)

#FeatureTypeUnitAllowed values
13
With communication interface analogue
L——
14
With communication interface AS-Interface
L——
15
With communication interface CANOpen
L——
16
With communication interface DeviceNet
L——
17
With communication interface Ethernet
L——
18
With communication interface INTERBUS
L——
19
With communication interface PROFIBUS
L——
20
With communication interface RS-232
L——
21
With communication interface RS-422
L——
22
With communication interface RS-485
L——
23
With communication interface SSD
L——
24
With communication interface SSI
L——
29
Type of interface for safety communication
A—

Measurements (4)

#FeatureTypeUnitAllowed values
37
Width sensor
Nmm—
38
Diameter sensor
Nmm—
39
Height of sensor
Nmm—
40
Length of sensor
Nmm—

Material (3)

#FeatureTypeUnitAllowed values
42
Material of optical surface
A—
43
Housing material
A—
58
Material of cable sheath
A—

Application (1)

#FeatureTypeUnitAllowed values
60
Suitable for safety functions
L——

Operating conditions (1)

#FeatureTypeUnitAllowed values
63
Ambient temperature
R°C—