EC003250 version 3

Power cable < 1 kV, for moving application

Published in
ETIM-10.0, ETIM-9.0
Also called
Cable, Cable for pendulum luminaire, Connection cable, Control cable, Device connection cable, Elevator cable, Energy cable < 1 kV, for moving application, Flat cable, Flexible cable, H05RR-F, H05VV-F, H07BQ-F, H07RN-F, Illumination cable, LiYY, Measuring conductor, Ribbon cable, Textile covered cable, Welding cable, YY

Measurements (9)

#FeatureTypeUnitAllowed values
3
AWG size
A—
8
Strand diameter
Nmm—
50
Cable width approximate
Nmm—
51
Cable height approximate
Nmm—
52
Outer diameter approximate
Nmm—
53
Min. permitted bending radius, moving application with forced guidance
Nmm—
54
Min. permitted bending radius, moving application/free movement
Nmm—
55
Min. permitted bending radius, stationary application/permanent installation
Nmm—
63
Weight
Nkg/km—

Connection (4)

#FeatureTypeUnitAllowed values
4
Nominal cross section conductor (AWG)
Nkcmil—
5
Nominal cross section conductor
Nmm²—
48
Nominal cross section pilot/reduced conductors
Nmm²—
49
Nominal cross section pilot/reduced conductors (AWG)
N——

Model/type (7)

#FeatureTypeUnitAllowed values
7
Number of strands per conductor
N——
10
Number of cores
N——
11
Number of stranding elements
N——
19
With protective conductor
L——
26
Cable geometry
A—
47
Number of pilot/reduced conductors
N——
60
Shape of conductor
A—

Electrical (3)

#FeatureTypeUnitAllowed values
9
Conductor resistance at 20 °C
NOhm/km—
58
Nominal voltage U0
NV—
59
Nominal voltage U
NV—

Options (5)

#FeatureTypeUnitAllowed values
17
Core identification according to HD 308 S2
L——
20
Drain wire
L——
25
Screen
L——
28
Torsion resistant
L——
46
Low temperature resistant according to EN 60811-504+505+506
L——

Mounting/installation (2)

#FeatureTypeUnitAllowed values
21
Suspension element
A—
61
Max. tensile strength during installation
NkN—

Colour (1)

Protection (12)

#FeatureTypeUnitAllowed values
27
Protective barrier
A—
31
Flame retardant according to IEC 60332-1-2
L——
32
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
L——
33
Flame retardant according to IEC 60332-3-22 (Cat A)
L——
34
Flame retardant according to IEC 60332-3-23 (Cat B)
L——
35
Flame retardant according to IEC 60332-3-24 (Cat C)
L——
36
Flame retardant according to IEC 60332-3-25 (Cat D)
L——
41
Reaction-to-fire according to EN 13501-6: Class
A—
42
Reaction-to-fire according to EN 13501-6: Smoke production
A—
43
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
A—
44
Reaction-to-fire according to EN 13501-6: Acidity
A—
45
Oil resistant according to EN IEC 60811-404
L——

Operating conditions (3)

#FeatureTypeUnitAllowed values
56
Permitted cable outer temperature during assembling/handling
R°C—
57
Permitted cable outer temperature after assembling without vibration
R°C—
62
Max. permitted conductor temperature
N°C—