EC003251 version 4
Power cable >= 1 kV, for permanent installation
- Published in
- ETIM-10.0
- Also called
- Airfield lighting cable, Airport lighting cable, Cable, Connection cable, Energy cable, Energy cable >= 1 kV, for permanent installation, Extra high voltage power cable, High voltage power cable, Ignition cable, Low voltage power cable, Marine cable, Medium voltage power cable, Offshore cable, Ship power cable, Shipboard cable, Shipboard low voltage cable
Material (10)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 1 | Conductor material | A | — | |
| 2 | Conductor surface | A | — | |
| 13 | Material core insulation | A | — | |
| 27 | Material armouring | A | — | |
| 34 | Material outer sheath | A | — | |
| 35 | Specification material outer sheath | A | — | |
| 47 | Low smoke according to EN IEC 61034-2 | L | — | — |
| 48 | Halogen free according to EN IEC 60754-1 | L | — | — |
| 49 | Halogen free according to EN IEC 60754-2 | L | — | — |
| 50 | Halogen free according to EN IEC 60754-3 | L | — | — |
Connection (5)
Measurements (8)
Other (6)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 7 | Conductor category | A | — | |
| 14 | Specification core insulation | A | — | |
| 16 | Core identification | A | — | |
| 26 | Armouring/reinforcement | A | — | |
| 32 | Concentric conductor | A | — | |
| 72 | Nominal equivalent cross section of reinforcement | N | mm² | — |
Model/type (8)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 8 | Number of strands per conductor | N | — | — |
| 11 | Shape of conductor | A | — | |
| 12 | Number of cores | N | — | — |
| 19 | With protective conductor | L | — | — |
| 29 | Number of pilot/reduced conductors | N | — | — |
| 37 | Cable geometry | A | — | |
| 74 | Suitable as installation cable | L | — | — |
| 79 | With rodent protection | L | — | — |
Electrical (3)
Options (10)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 15 | Core identification according to HD 308 S2 | L | — | — |
| 17 | Laminated sheath | L | — | — |
| 18 | Fibre optic elements | L | — | — |
| 20 | Inner semi-conducting layer | L | — | — |
| 21 | Outer semi-conducting layer | L | — | — |
| 22 | Screen | L | — | — |
| 23 | Drain wire | L | — | — |
| 24 | Lead sheath | L | — | — |
| 38 | Conductive coating | L | — | — |
| 59 | Circuit integrity according to EN 50200 annex E | L | — | — |
Protection (20)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 25 | Protective barrier | A | — | |
| 28 | Radial water blocking cable | L | — | — |
| 39 | Longitudinal water blocking conductors | L | — | — |
| 40 | Longitudinal water blocking screen | L | — | — |
| 41 | Flame retardant according to IEC 60332-1-2 | L | — | — |
| 42 | Flame retardant according to IEC 60332-3-21 (Cat A F/R) | L | — | — |
| 43 | Flame retardant according to IEC 60332-3-22 (Cat A) | L | — | — |
| 44 | Flame retardant according to IEC 60332-3-23 (Cat B) | L | — | — |
| 45 | Flame retardant according to IEC 60332-3-24 (Cat C) | L | — | — |
| 46 | Flame retardant according to IEC 60332-3-25 (Cat D) | L | — | — |
| 51 | Reaction-to-fire according to EN 13501-6: Class | A | — | |
| 52 | Reaction-to-fire according to EN 13501-6: Smoke production | A | — | |
| 53 | Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | A | — | |
| 54 | Reaction-to-fire according to EN 13501-6: Acidity | A | — | |
| 60 | Oil resistant according to EN IEC 60811-404 | L | — | — |
| 80 | EFDE0050local Insulation integrity according to DIN VDE 0472-814 | A | — | |
| 81 | EFDE0051local Circuit integrity according to DIN 4102-12 | A | — | |
| 82 | EFUK0001local Circuit integrity according to BS 6387 CWZ | L | — | — |
| 83 | EFUK0004local Circuit integrity according to BS 8434-2 | L | — | — |
| 84 | EFUK0005local Circuit integrity according to BS 8491 | A | — |
Colour (1)
Approval/certification (5)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 55 | Circuit integrity according to IEC 60331-1 | A | — | |
| 56 | Circuit integrity according to IEC 60331-2 | A | — | |
| 57 | Circuit integrity according to IEC 60331-3 | A | — | |
| 58 | Circuit integrity according to EN 50200 | A | — | |
| 78 | Certified as airport lighting cable | L | — | — |