EC004589 version 3
Mains protection device
- Published in
- ETIM-10.0
- Also called
- Digital protection relay, Microprocessor type protective relay, Numerical relay, Protective relay
Electrical (9)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 1 | Supply voltage AC 50 Hz | R | V | — |
| 2 | Supply voltage AC 60 Hz | R | V | — |
| 3 | Supply voltage DC | R | V | — |
| 4 | Voltage type (supply voltage) | A | — | |
| 36 | Undervoltage protection (ANSI 27) | L | — | — |
| 43 | Phase-sequence-voltage supervision (ANSI 47) | L | — | — |
| 48 | Voltage dependent overcurrent protection (ANSI 51V) | L | — | — |
| 50 | Overvoltage protection (ANSI 59) | L | — | — |
| 51 | Overvoltage protection, zero-sequence system (ANSI 59N) | L | — | — |
Model/type (2)
Options (20)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 6 | Expandable | L | — | — |
| 35 | Synchrocheck, synchronising function (ANSI 25) | L | — | — |
| 37 | Directional power supervision (ANSI 32) | L | — | — |
| 38 | Reverse power protection (ANSI 32R) | L | — | — |
| 39 | Undercurrent protection (ANSI 37) | L | — | — |
| 40 | Temperature supervision (ANSI 38) | L | — | — |
| 44 | Starting-time supervision (ANSI 48) | L | — | — |
| 45 | Thermal overload protection (ANSI 49) | L | — | — |
| 49 | Power factor (ANSI 55) | L | — | — |
| 52 | Current unbalance protection (ANSI 60) | L | — | — |
| 54 | Restart inhibit (ANSI 66) | L | — | — |
| 55 | Directional over-current protection (ANSI 67) | L | — | — |
| 56 | Power-swing blocking (ANSI 68) | L | — | — |
| 58 | Automatic reclosing (ANSI 79) | L | — | — |
| 59 | Frequency protection (ANSI 81) | L | — | — |
| 60 | Rate-of-frequency-change protection (ANSI 81R) | L | — | — |
| 61 | Under frequency load shedding (ANSI 81U) | L | — | — |
| 62 | Lockout (ANSI 86) | L | — | — |
| 67 | Differential protection, transformer (ANSI 87T) | L | — | — |
| 68 | Synchrophasor measurement (ANSI PMU) | L | — | — |
Connection (7)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 8 | Number of analogue inputs | N | — | — |
| 9 | Number of analogue outputs | N | — | — |
| 10 | Number of digital inputs | N | — | — |
| 11 | Number of digital outputs | N | — | — |
| 12 | Number of resistance temperature detector (RTD) inputs | N | — | — |
| 13 | Number of mA-outputs | N | — | — |
| 14 | Number of Arc-inputs | N | — | — |
Communication (13)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 15 | Supporting protocol for HSR | L | — | — |
| 16 | Supporting protocol for PRP | L | — | — |
| 17 | Supporting protocol for PTP | L | — | — |
| 18 | Supporting protocol for RSTP | L | — | — |
| 19 | Supporting protocol for DNP3 | L | — | — |
| 20 | Supporting protocol for IEC 60870-5-101 | L | — | — |
| 21 | Supporting protocol for IEC 60870-5-103 | L | — | — |
| 22 | Supporting protocol for IEC 60870-5-104 | L | — | — |
| 23 | Supporting protocol for IEC 61850-8-1 | L | — | — |
| 24 | Supporting protocol for IEC 61850-9-2 | L | — | — |
| 25 | Supporting protocol for Modbus | L | — | — |
| 26 | Supporting protocol for PROFIBUS | L | — | — |
| 27 | Supporting protocol for PROFINET IO | L | — | — |
Protection (17)
| # | Feature | Type | Unit | Allowed values |
|---|---|---|---|---|
| 28 | Protection functions for 1-pole tripping | L | — | — |
| 29 | Protection functions for 3-pole tripping | L | — | — |
| 30 | Switch On To Fault protection (SOTF) | L | — | — |
| 31 | Arc protection (ARC) | L | — | — |
| 32 | Locked rotor protection (ANSI 14) | L | — | — |
| 33 | Distance protection (ANSI 21/21N) | L | — | — |
| 34 | Overexcitation protection (ANSI 24) | L | — | — |
| 41 | Underexcitation protection (ANSI 40) | L | — | — |
| 42 | Unbalanced-load protection (ANSI 46) | L | — | — |
| 46 | Circuit-breaker failure protection (ANSI 50BF) | L | — | — |
| 47 | End fault protection (ANSI 50EF) | L | — | — |
| 53 | Sensitive ground-fault protection (ANSI 64) | L | — | — |
| 57 | Out-of-step protection (ANSI 78) | L | — | — |
| 63 | Differential protection, busbar (ANSI 87B) | L | — | — |
| 64 | Differential protection, generator (ANSI 87G) | L | — | — |
| 65 | Differential protection, line (ANSI 87L) | L | — | — |
| 66 | Differential protection, motor (ANSI 87M) | L | — | — |