EC004852 version 1

Hybrid air heater, directly fired, suspended

Published in
ETIM-10.0
Also called
AHU, Air handling unit, Air heater, hybrid, suspended, Air sourced heatpump (hybrid), Hybrid directly fired air heater, suspended

Model/type (6)

#FeatureTypeUnitAllowed values
1
Closed version
L——
2
Operation as open model (air supply) possible
L——
8
Fuel type
A—
17
Fan type
A—
20
Free-exhausting
L——
54
With suspension
L——

Performance (9)

#FeatureTypeUnitAllowed values
3
Total heating capacity
NkW—
4
Heating power gas heating
NkW—
5
Heat emission heat pump heat exchanger at 20 °C 35/30
NkW—
6
Cooling capacity heat pump heat exchanger at 27 °C 12/17
NkW—
7
Nominal load
RkW—
13
Efficiency
N%—
15
Air volume
Rm³/h—
16
Max. throw horizontal
Nm—
51
Sound pressure level at height of 5 metres
RdB(A)—

Operating conditions (2)

#FeatureTypeUnitAllowed values
9
Gas pre-pressure
Rmbar—
56
Max. operating pressure
NkPa—

Consumption (4)

#FeatureTypeUnitAllowed values
10
Gas consumption high-calorific natural gas (G20)
Nm³/h—
11
Gas consumption low-calorific natural gas (G25)
Nm³/h—
12
Gas consumption propane (G31)
Nkg/h—
34
Supplementary electricity consumption in standby-mode (Psb)
NW—

Energy efficiency/environmental (2)

#FeatureTypeUnitAllowed values
14
ηs, h (seasonal space heating energy efficiency)
N%—
59
Gas quality mark HR
L——

Setting/control (8)

#FeatureTypeUnitAllowed values
18
Adjustable induction in exhaust air
L——
19
Adjustable fins on exhaust side
L——
21
Burner controller high/low
L——
22
Modulating burner control
L——
23
Burner controller, pulsating
L——
24
Control signal on/off
L——
25
Control signal 0-10 V
L——
26
Control signal OpenTherm
L——

Communication (1)

#FeatureTypeUnitAllowed values
27
Supporting protocol for Modbus
L——

Electrical (4)

#FeatureTypeUnitAllowed values
28
Connection voltage
RV—
29
Number of phases
N——
30
Nominal current
NA—
31
Max. electric power input
NW—

Other (3)

#FeatureTypeUnitAllowed values
32
Frequency
A—
50
Manufacturer specific system components required
L——
55
Water-side resistance at dT 20 °C
NkPa—

Measurements (11)

#FeatureTypeUnitAllowed values
36
Nominal diameter fuel
A—
37
Outer pipe diameter fuel
Nmm—
41
Outer pipe diameter condensate
Nmm—
43
Nominal duct width, air supply
Nmm—
45
Nominal duct diameter, flue
Nmm—
46
Height
Nmm—
47
Width
Nmm—
48
Depth
Nmm—
49
Min. mounting height (horizontal air distribution)
Nm—
57
Water content
Nl—
58
Weight including filling
Nkg—

Mounting/installation (2)

#FeatureTypeUnitAllowed values
52
Suitable for wall mounting
L——
53
Suitable for in-roof mounting
L——