EC004892 versión 1
Transformer meter cabinet
- Publicada en
- ETIM-10.0
- También se llama
- Indirect meter cabinet, Load part, Meter cabinet, indirect measurement, Meter part, Transformer cabinet
Model/type (16)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 1 | Model | A | — | |
| 12 | Number of doors | N | — | — |
| 13 | Number of locks | N | — | — |
| 14 | Number of distributor rows | N | — | — |
| 15 | Number of fields | N | — | — |
| 16 | Number of meter panels, direct measurement | N | — | — |
| 17 | Number of indirect meters | N | — | — |
| 18 | Number of switching device panels | N | — | — |
| 21 | Type of meter | A | — | |
| 22 | Meter equipped with push-in distribution terminal block | L | — | — |
| 27 | With secondary wiring | L | — | — |
| 37 | Equipment of transformer compartment | A | — | |
| 40 | System configuration | A | — | |
| 43 | Test terminal, number of poles | N | — | — |
| 44 | Suitable for outdoor installation | L | — | — |
| 58 | EFDE0123local Number of compartments for additional devices | N | — | — |
Electrical (12)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 2 | Rated current | N | A | — |
| 3 | Continuous current Inc | N | A | — |
| 4 | Nominal voltage (Un) | N | V | — |
| 5 | Rated insulation voltage Ui | N | V | — |
| 7 | Surge current capacity | N | kA | — |
| 8 | Rated short-time withstand current lcw | N | kA | — |
| 9 | Conditioned rated short-circuit current Iq | N | kA | — |
| 10 | Rated impulse withstand voltage Uimp | N | kV | — |
| 11 | Power loss | N | W | — |
| 26 | With primary wiring | L | — | — |
| 36 | Type of control fuse | A | — | |
| 39 | Overvoltage protection | A | — |
Other (7)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 6 | Rated frequency | R | Hz | — |
| 34 | Disconnecting point, system side | A | — | NoneKnife blade fuse holderKnife blade fuse switch disconnectorKnife blade in-line fuse switch disconnector baseMiniature circuit breaker (MCB)Net and system protection according to VDE AR-N-4105 and VDE AR-N-4110Power-cut-out switchPower-cut-out switch with motor drivePower isolator with motor driveSwitch disconnector (low voltage)Other |
| 38 | Equipment of additional transformer meter compartment | A | — | |
| 46 | Impact strength | A | — | |
| 48 | Pollution degree | A | — | |
| 49 | Electromagnetic compatibility (EMC) | A | — | |
| 50 | Rated load factor RDF | N | — | — |
Options (3)
Mounting/installation (2)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 20 | With mounting plate | L | — | — |
| 30 | Mounting method | A | — |
Connection (7)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 24 | Meter equipped with control cable duct | L | — | — |
| 25 | With power supply connector | L | — | — |
| 31 | Connection space, power side | A | — | |
| 32 | Number of poles busbar (connection space, power side) | A | — | |
| 33 | Disconnecting point, power side | A | — | |
| 41 | Max. cross section connection cable | N | mm² | — |
| 42 | Max. cross section outgoing cable | N | mm² | — |
Application (1)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 29 | Suitable for metering transformer conversion board | L | — | — |
Protection (3)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 35 | Voltage path fuse protection | A | — | |
| 45 | Degree of protection (IP) | A | — | |
| 47 | Protection class according to IEC 61140 | A | — |
Colour (2)
Measurements (3)
Approval/certification (1)
| # | Feature | Tipo | Unidad | Valores permitidos |
|---|---|---|---|---|
| 57 | EFDE0001local VDE tested | L | — | — |