EC004916 version 1

Hot tap water boiler indirectly heated (multiple heat exchangers)

Published in
ETIM-10.0
Also called
Boiler, indirectly fired, Calorifier, Dual coil indirect calorifier, Hot tap water cylinder indirectly heated (multiple heat exchangers), Hot water cylinder

Measurements (18)

#FeatureTypeUnitAllowed values
5
Volume
Nl—
16
Height
Nmm—
17
Width
Nmm—
18
Depth
Nmm—
19
Diameter
Nmm—
20
Tilting height
Nmm—
22
Nominal diameter cold tap water
A—
23
Outer pipe diameter cold tap water
Nmm—
25
Nominal diameter hot tap water
A—
26
Outer pipe diameter hot tap water
Nmm—
31
Nominal diameter circulation pipe
A—
32
Outer pipe diameter circulation pipe
Nmm—
35
Nominal diameter indirect heating coil 1
A—
36
Outer pipe diameter indirect heating coil 1
Nmm—
42
Nominal diameter indirect heating coil 2
A—
43
Outer pipe diameter indirect heating coil 2
Nmm—
49
Nominal diameter indirect heating coil 3
A—
50
Outer pipe diameter indirect heating coil 3
Nmm—

Operating conditions (8)

#FeatureTypeUnitAllowed values
6
Max. operating pressure tank
Nbar—
7
Max. operating temperature tank
N°C—
38
Max. operating pressure indirect heating coil 1
Nbar—
39
Max. operating temperature indirect heating coil 1
N°C—
45
Max. operating pressure indirect heating coil 2
Nbar—
46
Max. operating temperature indirect heating coil 2
N°C—
52
Max. operating pressure indirect heating coil 3
Nbar—
53
Max. operating temperature indirect heating coil 3
N°C—

Model/type (9)

#FeatureTypeUnitAllowed values
8
Double separation
L——
9
Wall set-up
L——
11
With pressure reducing valve
L——
12
With pressure gauge
L——
13
With thermometer
L——
14
With cleaning opening
L——
33
Position heating coil 1
A—
40
Position heating coil 2
A—
47
Position heating coil 3
A—

Options (2)

#FeatureTypeUnitAllowed values
10
Vertical positioning
L——
15
Protective anode
L——

Connection (9)

#FeatureTypeUnitAllowed values
21
Cold tap water connection
A—
24
Hot tap water connection
A—
27
Connection, drainage connection
A—
28
Nominal diameter drain connection
A—
29
Outer pipe diameter drainage connection
Nmm—
30
Circulation pipe connection
A—
34
Connection indirect heating coil 1
A—
41
Connection indirect heating coil 2
A—
48
Connection indirect heating coil 3
A—

Performance (4)

#FeatureTypeUnitAllowed values
37
Max. transferable capacity 80/10-45 indirect heating coil 1
NkW—
44
Max. transferable capacity 80/10-45 indirect heating coil 2
NkW—
51
Max. transferable capacity 80/10-45 indirect heating coil 3
NkW—
55
Capacity profile
A—

Energy efficiency/environmental (2)

#FeatureTypeUnitAllowed values
54
ηwh (water heating energy efficiency)
N%—
56
Energy efficiency class
A—