EC010325 version 6

Fire-extinguishing unit

Published in
ETIM-10.0
Also called
—

Material (10)

#FeatureTypeUnitAllowed values
1
Material pump casing
A—
2
Material quality pump casing
A—
3
Material impeller/pump wheel
A—
4
Material quality impeller/pump wheel
A—
5
Material reservoir
A—
6
Material quality reservoir
A—
7
Material fittings
A—
8
Quality class fittings
A—
9
Material of unit pipework
A—
10
Quality class unit pipework
A—

Model/type (5)

#FeatureTypeUnitAllowed values
11
Number of pumps
N——
17
Type of drive
A—
68
Flange shape
A—
70
Suction operation
L——
71
With bypass pipe
L——

Performance (4)

#FeatureTypeUnitAllowed values
12
Volume flow rate (BEP)
Nm³/h—
13
Discharge head at flow rate (BEP)
NkPa—
14
Max. discharge flow
Nm³/h—
27
Rotational speed
N1/min—

Measurements (5)

#FeatureTypeUnitAllowed values
15
Max. static height
Nm—
19
Cable length
Nm—
75
Length
Nmm—
76
Width
Nmm—
77
Height
Nmm—

Operating conditions (3)

#FeatureTypeUnitAllowed values
16
Max. operating pressure
Nbar—
56
Medium temperature (continuous)
R°C—
57
Ambient temperature
R°C—

Connection (10)

#FeatureTypeUnitAllowed values
18
Electrical connection
A—
28
Motor speed control
A—
58
Connection inlet side
A—
59
Nominal diameter connection inlet side
A—
60
Outer pipe diameter connection inlet side
Nmm—
61
Flange compression stage connection inlet side
A—
63
Connection outlet side
A—
64
Nominal diameter connection outlet side
A—
65
Outer pipe diameter connection outlet side
Nmm—
66
Flange compression stage connection outlet side
A—

Electrical (5)

#FeatureTypeUnitAllowed values
20
Rated voltage
RV—
21
Number of phases
N——
23
Nominal current
NA—
24
Motor power input (P1) per motor
NkW—
25
Motor power output (P2) per motor
NkW—

Other (1)

#FeatureTypeUnitAllowed values
22
Frequency
A—

Setting/control (1)

#FeatureTypeUnitAllowed values
29
Type of speed control
A—

Communication (16)

#FeatureTypeUnitAllowed values
30
Communication
A—
37
Interface signal 0-10 V / 2-10 V
L——
38
Interface signal 0-20 mA / 4-20 mA
L——
43
With communication interface RS-485
L——
44
With communication interface RS-232
L——
45
Supporting protocol for EtherNet/IP
L——
46
Supporting protocol for KNX
L——
47
Supporting protocol for PROFIBUS
L——
48
Supporting protocol for PROFINET IO
L——
49
Supporting protocol for CAN/CANOpen
L——
50
Supporting protocol for Modbus TCP
L——
51
Supporting protocol for Modbus RTU
L——
52
Supporting protocol for BACnet MS/TP
L——
53
Supporting protocol for BACnet IP
L——
54
Supporting protocol for LON/LONWorks
L——
55
Supporting protocol for LIN Bus
L——

Options (11)

#FeatureTypeUnitAllowed values
31
Radio standard Bluetooth
L——
32
Radio standard WLAN 802.11
L——
33
Mobile communications standard 2G (GSM)
L——
34
Mobile communications standard 3G (UMTS)
L——
35
Mobile communications standard 4G (LTE)
L——
36
Mobile communications standard 5G
L——
39
Interface PT100 / PT1000 / PTC
L——
40
Interface Pulse Width Modulation (PWM)
L——
41
Interface pulse counter
L——
42
Potential free switch contact
L——
72
Switches via fire alarm
L——

Application (1)

#FeatureTypeUnitAllowed values
69
Suitable for building above 70 metres high
L——