EC010367 version 5

Fitting with 6 connections

Published in
ETIM-10.0
Also called
Ball piece with 6 connections

Material (5)

#FeatureTypeUnitAllowed values
1
Material
A—
2
Material quality
A—
Al 99.0 (3.0205)Al 99.5 (3.0255)Al 99.9 (3.0305)Aluminium bronzeBronze (Rg 5)Bronze (Rg 7)Bronze (Rg 12)Zinc-poor bronze (Rg 10)Zinc-free bronze (90/10)Cu-DHP (CW024A)CuNi10Fe1MnCuSn4Zn2PS
78 moreCuNi10Fe1.6MnCuSn5Zn5Pb2CuSn5Zn5Pb5-CCuZn21Si3P (CW724R)CuZn35Pb2Al-C-GMCuZn33Pb1.5AlAs (CW626N)CuZn36Pb3 (CW603N)CuZn39Pb2 (CW612N)CuZn36Pb2As (CW602N)CuZn39Pb3 (CW614N)EN AW-5083 (AlMg4.5Mn)CuZn38AsEN AW-5754 (AlMg3)EN AW-6060 T5(AlMgSi)EN AW-6082 T6(AlSi1MgMn)CuZn40Pb2 (CW617N)EN-GJMW-400-5 (EN-JM1030)Ethylene-propylene diene monomer rubber (EPDM)Alloyed steelCast iron EN-GJL-200 (GG 20)Cast iron EN-GJL-250 (GG 25)Cast iron EN-GJS-400-15 (GGG 40)Cast iron EN-GJS-400-18 (GGG 40.3)Cast iron EN-GJS-500-7 (GGG 50)Malleable cast ironCast steelStonewareFibre-reinforced plasticDezincification resistant brass (DZR)NBR (nitrile rubber)PE-40PE-50PE-80PE-100PE-S2PE diffusion-tightPP-CPP-GFPP-HPP-MDPP-MXPP-RPP-SPVC-CPVC-CPEPVC recycledPVC-OPVC-URst 37.2 (1.0038)Rst 37.3 N (1.0116)Rst 37.3 U (1.0114)Stainless steel 304 (1.4301)Stainless steel 304 L (1.4306)Stainless steel 316 (1.4401)Stainless steel 316 L (1.4404)Stainless steel 316 Ti (1.4571)Stainless steel 321 (1.4541)Forged steelSt 33 (1.0035)St 34.2 (1.0034)St 35 (1.0308)St 35.8 (1.0305)St 37 (1.0254)St 37.2 (1.0037)St 37.8 (1.0345)St 44.0 (1.0256)St 44.2 (1.0044)St 44.3 annealed (1.0144)St 44.3 unannealed (1.0431)St 50.2 (1.0050)St 52.0 (1.0421)St 52.3 annealed (1.0570)St 52.3 unannealed (1.0553)St 60.2 (1.0060)St 70.2 (1.0070)TT St 35 N (1.0356)Ust 37.2 (1.0036)Other
3
Surface protection
A—
4
Surface treatment
A—
40
Material sealing
A—

Model/type (6)

#FeatureTypeUnitAllowed values
5
Model
A—
6
Multi-part
L——
61
With sealing rings/gaskets
L——
62
With thermal insulation
L——
63
With buffer stud
L——
69
With sound decoupling
L——

Options (3)

#FeatureTypeUnitAllowed values
7
Reducing
L——
8
System specific
L——
68
Thermal separation
L——

Connection (45)

#FeatureTypeUnitAllowed values
9
Nominal diameter connection 1
A—
10
Outer pipe diameter connection 1
Nmm—
11
Wall thickness, connection 1
Nmm—
12
Wall thickness connecting pipe, connection 1
Nmm—
13
Connection 1
A—
14
Nominal diameter connection 2
A—
15
Outer pipe diameter connection 2
Nmm—
16
Wall thickness, connection 2
Nmm—
17
Wall thickness connecting pipe, connection 2
Nmm—
18
Connection 2
A—
19
Nominal diameter connection 3
A—
20
Outer pipe diameter connection 3
Nmm—
21
Wall thickness, connection 3
Nmm—
22
Wall thickness connecting pipe, connection 3
Nmm—
23
Connection 3
A—
24
Nominal diameter connection 4
A—
25
Outer pipe diameter connection 4
Nmm—
26
Wall thickness, connection 4
Nmm—
27
Wall thickness connecting pipe, connection 4
Nmm—
28
Connection 4
A—
29
Nominal diameter connection 5
A—
30
Outer pipe diameter connection 5
Nmm—
31
Wall thickness, connection 5
Nmm—
32
Wall thickness connecting pipe, connection 5
Nmm—
33
Connection 5
A—
34
Nominal diameter connection 6
A—
35
Outer pipe diameter connection 6
Nmm—
36
Wall thickness, connection 6
Nmm—
37
Wall thickness connecting pipe, connection 6
Nmm—
38
Connection 6
A—
42
Length of connection 1
Nmm—
43
Working length connection 1
Nmm—
44
Length of connection 2
Nmm—
45
Working length connection 2
Nmm—
46
Length of connection 3
Nmm—
47
Working length connection 3
Nmm—
48
Length of connection 4
Nmm—
49
Working length connection 4
Nmm—
50
Length of connection 5
Nmm—
51
Working length connection 5
Nmm—
52
Length of connection 6
Nmm—
54
Working length connection 6
Nmm—
56
Angle, connection 3-4
N°—
57
Angle, connection 4-5
N°—
58
Angle, connection 5-6
N°—

Other (2)

#FeatureTypeUnitAllowed values
39
Contour code
A—
59
Ring stiffness class
A—

Colour (1)

#FeatureTypeUnitAllowed values
41
Main colour fitting
A—

Operating conditions (2)

#FeatureTypeUnitAllowed values
53
Medium temperature (continuous)
R°C—
55
Max. operating pressure at 20 °C
Nbar—

Measurements (1)

#FeatureTypeUnitAllowed values
60
Standard Dimension Ratio (SDR)
N——

Approval/certification (11)

#FeatureTypeUnitAllowed values
64
FM quality mark
L——
65
LPCB quality mark
L——
66
ULC quality mark
L——
67
UL quality mark
L——
70
VdS quality mark
L——
71
DVGW quality mark for gas
L——
72
DVGW quality mark for water
L——
73
KIWA certified
L——
74
Gastec QA mark
L——
75
KOMO certified
L——
77
Type approval according to BBR/EKS
L——

Energy efficiency/environmental (1)

#FeatureTypeUnitAllowed values
76
Gastec QA - AR 214 (H2)
L——