EC011285 version 6

Heat recovery unit (residential)

Published in
ETIM-10.0
Also called
Heat recovery unit for domestic construction, Heat recovery unit for housing construction, Heat recovery unit for residential construction, Heat recovery unit for single family house, Heat recovery ventilator for domestic construction, HRV, Ventilation appliance

Model/type (15)

#FeatureTypeUnitAllowed values
1
Heat recovery by
A—
22
Type of motor
A—
28
With thermal overload protection
L——
31
Type of switch
A—
32
With digital display
L——
33
With wired control unit
L——
39
With zone controller
L——
41
With heating element
L——
42
With volatile organic compound (VOC) sensor
L——
44
With external humidity (RH) sensor
L——
45
With internal humidity (RH) sensor
L——
47
With internal carbon dioxide (CO2) sensor
L——
50
With bypass
L——
51
With constant pressure control
L——
52
With constant volume flow control
L——

Material (3)

Mounting/installation (5)

#FeatureTypeUnitAllowed values
5
Suitable for wall mounting
L——
6
Suitable for ceiling mounting
L——
7
Suitable for floor mounting
L——
8
Suitable for mounting in suspended ceiling
L——
9
Suitable for mounting in an attic
L——

Options (1)

#FeatureTypeUnitAllowed values
10
Left/right orientation reversible
L——

Other (2)

#FeatureTypeUnitAllowed values
11
Max. air volume at 50 Pa
Nm³/h—
63
Max. number of wet zones
N——

Performance (10)

#FeatureTypeUnitAllowed values
12
Max. air volume at 100 Pa
Nm³/h—
13
Max. air volume at 150 Pa
Nm³/h—
14
Max. air volume at 200 Pa
Nm³/h—
15
Max. air volume at 250 Pa
Nm³/h—
16
Max. air volume at 300 Pa
Nm³/h—
17
Max. volume flow according to 1254/2014/EU
Nm³/h—
19
Sound pressure level
NdB(A)—
21
Thermal efficiency at 70 % air volume at 50 Pa
N%—
65
Efficiency supply filter according to ISO 16890-1:2016
N%—
67
Efficiency exhaust filter according to ISO 16890-1:2016
N%—

Energy efficiency/environmental (3)

#FeatureTypeUnitAllowed values
18
Sound power level according to 1254/2014/EU
NdB(A)—
30
Energy efficiency class according to 1253/2014/EU
A—
80
Weighted average power according to RT 2005
NW-Th-C—

Electrical (6)

#FeatureTypeUnitAllowed values
20
Power consumption at max. air volume at 100 Pa
NW—
23
Voltage
NV—
24
Frequency
NHz—
25
Number of phases
N——
26
Fuse size of the device
NA—
27
Power electric heating element
RW—

Connection (10)

#FeatureTypeUnitAllowed values
29
Electrical connection
A—
49
Suitable for central heating boiler connection
L——
55
Connections outdoor air side
A—
56
Connections residential side
A—
57
Residential connection, underside
L——
58
Residential connection, left side
L——
59
Residential connection, right side
L——
60
Residential connection, top
L——
61
Roof connection, side
L——
62
Roof connection, top
L——

Application (12)

#FeatureTypeUnitAllowed values
34
Suitable for wired control unit
L——
40
Suitable for zone controller
L——
43
Suitable for extra VOC sensor
L——
46
Suitable for (extra) humidity (RH) sensor
L——
48
Suitable for (extra) carbon dioxide (CO2) sensor
L——
73
Suitable for a one-room dwelling acc. to decree nr. 87-149 and law 96-1107
L——
74
Suitable for a two-room dwelling acc. to decree nr. 87-149 and law 96-1107
L——
75
Suitable for a three-room dwelling acc. to decree nr. 87-149 and law 96-1107
L——
76
Suitable for a four-room dwelling acc. to decree nr. 87-149 and law 96-1107
L——
77
Suitable for a five-room dwelling acc. to decree nr. 87-149 and law 96-1107
L——
78
Suitable for a six-room dwelling acc. to decree nr. 87-149 and law 96-1107
L——
79
Suitable for a seven-room dwelling acc. to decree nr. 87-149 and law 96-1107
L——

Setting/control (3)

#FeatureTypeUnitAllowed values
35
With wireless remote control
L——
36
Suitable for wireless remote control
L——
38
Operation by app
L——

Communication (1)

#FeatureTypeUnitAllowed values
37
Supporting protocol for Modbus
L——

Measurements (5)

#FeatureTypeUnitAllowed values
54
Nominal duct diameter
Rmm—
68
Height
Nmm—
69
Width
Nmm—
70
Depth
Nmm—
72
Weight
Nkg—

Approval/certification (2)

#FeatureTypeUnitAllowed values
64
Supply filter according to ISO 16890-1:2016
A—
66
Exhaust filter according to ISO 16890-1:2016
A—