EC003248 version 3

Power cable < 1 kV, for permanent installation

Published in
ETIM-10.0, ETIM-9.0
Also called
Cable, Energy cable < 1 kV, for permanent installation, House wiring cable, Installation cable for under plaster, In-wall installation cable, Low voltage power cable, Offshore cable, Ship power cable, Shipboard cable, Shipboard low voltage cable, Solar cable

Connection (4)

#FeatureTypeUnitAllowed values
3
Nominal cross section conductor
Nmm²—
5
Nominal cross section conductor (AWG)
Nkcmil—
27
Nominal cross section pilot/reduced conductors
Nmm²—
28
Nominal cross section pilot/reduced conductors (AWG)
N——

Measurements (8)

#FeatureTypeUnitAllowed values
4
AWG size
A—
6
Diameter conductor
Nmm—
55
Cable width approximate
Nmm—
56
Cable height approximate
Nmm—
57
Outer diameter approximate
Nmm—
61
Min. permitted bending radius, stationary application/permanent installation
Nmm—
70
Weight
Nkg/km—
72
Strand diameter
Nmm—

Electrical (3)

#FeatureTypeUnitAllowed values
8
Conductor resistance at 20 °C
NOhm/km—
60
Nominal voltage U0
NV—
63
Nominal voltage U
NV—

Model/type (8)

#FeatureTypeUnitAllowed values
9
Number of cores
N——
17
With protective conductor
L——
26
Number of pilot/reduced conductors
N——
29
With rodent protection
L——
33
Cable geometry
A—
65
Shape of conductor
A—
66
Suitable as installation cable
L——
71
Number of strands per conductor
N——

Options (7)

#FeatureTypeUnitAllowed values
10
Twisted cores
L——
13
Core identification according to HD 308 S2
L——
19
Screen
L——
20
Drain wire
L——
21
Lead sheath
L——
52
Circuit integrity according to EN 50200 annex E
L——
54
Low temperature resistant according to EN 60811-504+505+506
L——

Operating conditions (3)

#FeatureTypeUnitAllowed values
18
Max. permitted conductor temperature
N°C—
58
Permitted cable outer temperature during assembling/handling
R°C—
59
Permitted cable outer temperature after assembling without vibration
R°C—

Protection (18)

#FeatureTypeUnitAllowed values
22
Protective barrier
A—
25
Radial water blocking cable
L——
34
Flame retardant according to IEC 60332-1-2
L——
35
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
L——
36
Flame retardant according to IEC 60332-3-22 (Cat A)
L——
37
Flame retardant according to IEC 60332-3-23 (Cat B)
L——
38
Flame retardant according to IEC 60332-3-24 (Cat C)
L——
39
Flame retardant according to IEC 60332-3-25 (Cat D)
L——
44
Reaction-to-fire according to EN 13501-6: Class
A—
45
Reaction-to-fire according to EN 13501-6: Smoke production
A—
46
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
A—
47
Reaction-to-fire according to EN 13501-6: Acidity
A—
53
Oil resistant according to EN IEC 60811-404
L——
73
Insulation integrity according to DIN VDE 0472-814
A—
74
Circuit integrity according to DIN 4102-12
A—
75
Circuit integrity according to BS 6387 CWZ
L——
76
Circuit integrity according to BS 8434-2
L——
77
Circuit integrity according to BS 8491
A—

Approval/certification (5)

#FeatureTypeUnitAllowed values
48
Circuit integrity according to IEC 60331-1
A—
49
Circuit integrity according to IEC 60331-2
A—
50
Circuit integrity according to IEC 60331-3
A—
51
Circuit integrity according to EN 50200
A—
68
Certified as airport lighting cable
L——

Mounting/installation (2)

#FeatureTypeUnitAllowed values
62
Suitable for underground installation
L——
69
Max. tensile strength during installation
NkN—

Application (1)

#FeatureTypeUnitAllowed values
67
Certified for shipboard application
L——