| EF021218 | Output signal (humidity) | A | — |
| EF021219 | Output signal (temperature) | A | — |
| EF021220 | Shape of passage | A | Model/type |
| EF021221 | Lead flashing on all sides | L | Options |
| EF021222 | Suitable for pitched roof | L | Application |
| EF021223 | Heat recovery connection | L | Connection |
| EF021224 | Nominal diameter, connection 1 | N | Connection |
| EF021225 | Nominal diameter, connection 2 | N | Connection |
| EF021226 | Roof flashing with angled piece | L | Options |
| EF021227 | Angled piece diameter | N | Measurements |
| EF021228 | Outer diameter of lip ring | N | Measurements |
| EF021229 | Position of lips | A | Other |
| EF021230 | Suitable for PPS flue pipe | L | Application |
| EF021231 | Suitable for aluminium flue pipe | L | Application |
| EF021232 | Suitable for stainless steel flue pipe | L | Application |
| EF021233 | Nominal diameter of insert end | N | Measurements |
| EF021234 | Nominal diameter of push-on end | N | Measurements |
| EF021235 | Working depth | N | Measurements |
| EF021236 | Air supply connection | L | Connection |
| EF021237 | Flue connection | L | Connection |
| EF021238 | Mechanical ventilation/heat recovery connection | L | Connection |
| EF021239 | Sewer de-aeration connection | L | Connection |
| EF021240 | Concentric flue/air supply | L | Options |
| EF021241 | Air supply diameter | N | Measurements |
| EF021242 | Diameter of mechanical ventilation/heat recovery | N | Measurements |
| EF021243 | Diameter of sewer de-aeration | N | Measurements |
| EF021244 | Diameter of concentric flue/air supply | A | — |
| EF021245 | Suitable for full plastic pipes | L | — |
| EF021246 | Suitable for plastic multi-layer pipes | L | Application |
| EF021247 | Suitable for copper pipes, chromium-plated | L | — |
| EF021248 | Suitable for steel pipes, thin-walled | L | — |
| EF021249 | Suitable for steel pipes, thick-walled | L | — |
| EF021250 | Size of radiator connection | A | Connection |
| EF021251 | Kv value | R | Other |
| EF021252 | Shortened construction length | L | Measurements |
| EF021253 | Reverse direction of flow | L | Options |
| EF021255 | Kv 2 value | N | Other |
| EF021256 | Temperature probe at distance | L | — |
| EF021257 | Length of cable/capillary tube to remote sensor | N | Measurements |
| EF021258 | Max. length of cable/capillary tube to remote control element | N | Measurements |
| EF021259 | Diameter remote sensor | N | Measurements |
| EF021260 | Length remote sensor | N | Measurements |
| EF021261 | Suitable for radiator | L | Application |
| EF021262 | Temperature sensor model | A | Model/type |
| EF021263 | Suitable for immersion tube | L | Application |
| EF021264 | Suitable for heater/cooler | L | — |
| EF021265 | Suitable for tap water | L | Application |
| EF021266 | Connection size insert probe | A | Connection |
| EF021268 | Support block lockable | L | Options |
| EF021269 | Support block adjustable | L | Setting/control |