| EF000001 | Nominal current | N |
| EF000002 | Nominal voltage | N |
| EF000034 | Frequency | N |
| EF000035 | Lamp power | N |
| EF000047 | Amperage | N |
| EF000054 | Number of poles | A |
| EF000104 | Supply voltage | N |
| EF000105 | Mains voltage | N |
| EF000106 | Input voltage | N |
| EF000107 | Output voltage | N |
| EF000111 | Operating voltage | N |
| EF000145 | Current supply | A |
| EF000187 | Voltage type | A |
| EF000188 | Switching current | N |
| EF000213 | Voltage | N |
| EF000227 | Rated current | N |
| EF000228 | Rated voltage | N |
| EF000232 | Max. connected load | N |
| EF000233 | Power supply system | A |
| EF000260 | Max. lamp power | N |
| EF000280 | Suitable for lamp power | R |
| EF000287 | For transformer power | N |
| EF000346 | Power consumption | N |
| EF000351 | Number of phases | N |
| EF000414 | Current measuring range, AC | R |
| EF000415 | Current measuring range, DC | R |
| EF000417 | Current measuring range | R |
| EF000421 | Lightning impulse current (10/350 µs) | N |
| EF000446 | Connected load | N |
| EF000465 | Nominal input additional heating system | N |
| EF000466 | Standby power consumption/24 h | N |
| EF000508 | Power adaptor | A |
| EF000523 | Max. engine power | N |
| EF000559 | Max. amperage | N |
| EF000579 | Separate power supply | L |
| EF000587 | Electricity consumption | N |
| EF000590 | Isolation resistance measuring range | R |
| EF000593 | Protective ground resistance measuring range | R |
| EF000620 | Max. power supply | N |
| EF000646 | Voltage change | A |
| EF000719 | Power cooking plate 1 | N |
| EF000720 | Power cooking plate 2 | N |
| EF000824 | Max. microwave power | N |
| EF000876 | Impedance | N |
| EF000877 | Max. current (Imax) | N |
| EF000879 | Number of conductors | N |
| EF000889 | Release characteristic | A |
| EF000957 | Number of control current circuits | N |
| EF001003 | Max. power consumption | N |
| EF001090 | Frequency supply voltage | N |
| EF001148 | Number of conductors (without earthing) | N |
| EF001280 | Number of groups/phases | N |
| EF001291 | Lamp power of fluorescent batten | N |
| EF001294 | Number of cores wiring | N |
| EF001313 | Switching power | N |
| EF001314 | Motor power | N |
| EF001315 | Max. output current | N |
| EF001325 | Max. switching current (resistive load) | N |
| EF001332 | Overvoltage protection | L |
| EF001334 | Special power supply | A |
| EF001345 | Number of conductors per cable | N |
| EF001364 | Rated operation power at AC-3, 400 V | N |
| EF001366 | Rated insulation voltage Ui | N |
| EF001378 | Rated operation current Ie, 400 V | N |
| EF001385 | Rated operation current Ie at AC-15, 230 V | N |
| EF001386 | Rated operation current Ie at DC-13, 230 V | N |
| EF001389 | Rated permanent current Iu | N |
| EF001390 | With integrated under voltage release | L |
| EF001391 | Number of poles | N |
| EF001392 | Rated operation current Ie at AC-3, 400 V | N |
| EF001393 | Rated operation current Ie at AC-1, 400 V | N |
| EF001399 | With integrated voltage decreasing resistor | L |
| EF001409 | Switching capacity at AC-3, 240 V | N |
| EF001428 | Input current at signal 1 | N |
| EF001435 | Rated operating voltage | R |
| EF001443 | Rated operation current Ie | N |
| EF001444 | Conditioned rated short-circuit current Iq | N |
| EF001469 | Type of power supply | A |
| EF001470 | Secondary voltage | N |
| EF001503 | Max. switching power | N |
| EF001507 | Max. output power | N |
| EF001509 | Max. control current | N |
| EF001536 | Max. load current | N |
| EF001561 | Integrated power adaptor | L |
| EF001615 | Nominal voltage U | N |
| EF001628 | Characteristic impedance | N |
| EF001711 | Voltage level | A |
| EF001732 | Max. starting current | N |
| EF001741 | Switching current (resistive) | N |
| EF001790 | Nominal voltage U0 | N |
| EF001854 | Max. resistance test value | N |
| EF001855 | Interference fixed voltage > 50 V AC/DC | L |
| EF001876 | Differential current | L |
| EF001913 | Earth bond voltage drop measuring range | R |
| EF001924 | Number of voltage input channels | N |
| EF001942 | Current carrying capacity | N |
| EF001950 | Nominal power consumption | N |
| EF001985 | Battery capacity | N |
| EF002013 | Mains supply | L |
| EF002048 | Power rating | N |
| EF002136 | Nominal connection power | N |
| EF002189 | Control power | N |
| EF002238 | Connected load heating element | N |
| EF002336 | Overload release current setting | R |
| EF002353 | Suitable for emergency power with DC supply | L |
| EF002355 | Voltage | R |
| EF002358 | Rated fault current | N |
| EF002384 | Overload protector | R |
| EF002417 | Rated operation current Ie at AC-21, 400 V | N |
| EF002418 | Rated operating voltage Ue | R |
| EF002431 | Resistance | N |
| EF002486 | Voltage measuring range | R |
| EF002489 | Voltage measuring range/AC direct | R |
| EF002533 | Supply voltage for defect-indication | R |
| EF002560 | Leakage current type | A |
| EF002562 | Short-circuit breaking capacity (Icw) | N |
| EF002563 | Rated switching capacity | N |
| EF002564 | Surge current capacity | N |
| EF002568 | Current limiting class | N |
| EF002569 | Overvoltage category | N |
| EF002578 | Rated surge voltage invariability | N |
| EF002647 | IEC-amperage | N |
| EF002648 | Amperage according to UL/CSA (for UL-version) | N |
| EF002668 | Supply voltage for indication | R |
| EF002669 | Voltage type for indication | A |
| EF002670 | Number of potentials | N |
| EF002676 | Voltage type for defect indication | A |
| EF002736 | Motor voltage | N |
| EF002952 | Control voltage 1 | R |
| EF002953 | Control voltage 2 | R |
| EF002954 | Type of control voltage 1 | A |
| EF002955 | Type of control voltage 2 | A |
| EF002956 | Frequency control voltage 1 | R |
| EF002957 | Frequency control voltage 2 | R |
| EF002981 | Nominal switching current at 250 V, potential free | N |
| EF002982 | Nominal switching current at 230 V, not potential free | N |
| EF002991 | Voltage type (supply voltage) | A |
| EF002993 | Rated surge voltage | N |
| EF003033 | Type of voltage (input voltage) | A |
| EF003034 | Power output | N |
| EF003092 | Output voltage stabilized | L |
| EF003202 | Output current | N |
| EF003215 | Output voltage at digital output | R |
| EF003218 | Output current at digital output | N |
| EF003287 | Switching current for digital outputs | N |
| EF003292 | External power supply required | L |
| EF003338 | With integrated power supply | L |
| EF003390 | Single-phase under voltage possible | L |
| EF003391 | Three-phase under voltage possible | L |
| EF003392 | Single-phase overvoltage possible | L |
| EF003393 | Three-phase overvoltage possible | L |
| EF003399 | Type of voltage measuring range | A |
| EF003405 | Single-phase under current possible | L |
| EF003406 | Three-phase under current possible | L |
| EF003407 | Single-phase overcurrent possible | L |
| EF003408 | Three-phase overcurrent possible | L |
| EF003419 | Line capacity | N |
| EF003525 | Voltage protection level | N |
| EF003586 | Switching voltage | N |
| EF003625 | Connection voltage | N |
| EF003648 | Max. switching current | N |
| EF003696 | Short-circuit protected | L |
| EF003705 | Nominal operating current | N |
| EF003775 | Primary voltage | N |
| EF003776 | Secondary voltage 1 | N |
| EF003777 | Secondary voltage 2 | N |
| EF003778 | Secondary voltage 3 | N |
| EF003779 | Secondary amperage 1 | N |
| EF003780 | Secondary amperage 2 | N |
| EF003781 | Secondary amperage 3 | N |
| EF003840 | Input voltage | R |
| EF003877 | Nominal current socket outlet | N |
| EF003887 | Switch capacity HVAC | R |
| EF003888 | Switching current for fluorescent lamps | N |
| EF003894 | Control current | N |
| EF003925 | With power adaptor | L |
| EF003933 | Output voltage | R |
| EF003975 | Rated fault current | R |
| EF003977 | Rated voltage | R |
| EF003978 | Rated control supply voltage AC 50 Hz | R |
| EF003979 | Rated control supply voltage AC 60 Hz | R |
| EF003980 | Rated control supply voltage DC | R |
| EF003981 | Rated current Iu | R |
| EF003983 | Operating voltage | R |
| EF003992 | Continuity resistance | N |
| EF003993 | With power supply module | L |
| EF004028 | No-load current | N |
| EF004035 | Max. output current at protected output | N |
| EF004037 | Max. current carrying capacity per I/O signal | N |
| EF004038 | Max. current carrying capacity per socket | N |
| EF004039 | Max. total current | N |
| EF004045 | Min. output current | N |
| EF004055 | Rated operation current of the motor | R |
| EF004056 | With motor current parameter setting | L |
| EF004102 | Switching voltage of OSSD at state "high" | N |
| EF004127 | Supply voltage | R |
| EF004148 | Connected load | R |
| EF004149 | Fuse size of the device | N |
| EF004193 | Follow current extinguishing capability | N |
| EF004198 | Max. continuous voltage AC | N |
| EF004214 | Nominal discharge surge current (8/20) | N |
| EF004215 | Total discharge current (8/20) (L+N-PE) | N |
| EF004216 | Nominal discharge surge current (8/20) (L-N) | N |
| EF004219 | Nominal load current | N |
| EF004220 | Nominal voltage AC | N |
| EF004221 | Nominal voltage DC | N |
| EF004233 | Voltage protection level core/core | N |
| EF004234 | Voltage protection level core/earth | N |
| EF004236 | Voltage protection level L-N | N |
| EF004237 | Voltage protection level L-PE/N-PE | N |
| EF004239 | Signal - max. continuous voltage AC | N |
| EF004240 | Signal - max. continuous voltage DC | N |
| EF004242 | Signal nominal discharge surge current (8/20) | N |
| EF004243 | Signal nominal load current | N |
| EF004244 | Signal nominal voltage AC | N |
| EF004245 | Signal nominal voltage DC | N |
| EF004246 | Signal safety level core/core | N |
| EF004247 | Signal safety level core/earth | N |
| EF004280 | Lamp power filament 1 | N |
| EF004281 | Lamp power filament 2 | N |
| EF004285 | Max. electrical capacity per phase | N |
| EF004298 | Nominal voltage | A |
| EF004349 | Nominal output power AC | N |
| EF004382 | Just-operate current | R |
| EF004515 | Rated voltage light sensor | N |
| EF004517 | Rated current (control contacts) | N |
| EF004584 | DC-system voltage | N |
| EF004598 | Dim capacity per channel | N |
| EF004649 | Engaging threshold power | R |
| EF004650 | Engaging threshold current | R |
| EF004655 | Electrical lifetime (control contacts) | N |
| EF004687 | Frequency supply voltage | R |
| EF004745 | Device conduction current | L |
| EF004777 | Max. continuous voltage DC | N |
| EF004838 | Lowest resolution, DC voltage | A |
| EF004839 | Lowest resolution, DC current | A |
| EF004840 | Lowest resolution, AC voltage | A |
| EF004841 | Lowest resolution, AC current | A |
| EF004843 | Lowest input sensitivity | N |
| EF004859 | Short-circuit current | N |
| EF004860 | Short-time peak load | N |
| EF004863 | Charging voltage | R |
| EF004891 | Open circuit voltage | N |
| EF004896 | Power tolerance | R |
| EF004919 | Max. switching power (control contacts) | N |
| EF004920 | Max. switching current (cos phi = 0.6) | N |
| EF004941 | Max. continuous current | N |
| EF004942 | Max. input power DC | N |
| EF004943 | Max. input voltage | N |
| EF004944 | Max. input current | N |
| EF004952 | Max. incandescent lamp load | N |
| EF004958 | Max. loading current | N |
| EF004971 | Max. load fluorescent lamp | N |
| EF004972 | Max. load fluorescent lamp (Duo circuit) | N |
| EF004973 | Max. load fluorescent lamp (parallel compensated) | N |
| EF004981 | Max. switching voltage (control contacts) | N |
| EF004989 | Max. voltage measuring range AC | N |
| EF004990 | Max. voltage measuring range DC | N |
| EF004991 | Max. current measuring range, AC | N |
| EF004992 | Max. current measuring range, DC | N |
| EF004993 | Max. system voltage | N |
| EF004996 | Max. power loss | N |
| EF004997 | Max. resistance measuring range | N |
| EF005003 | Mechanical lifetime (control contacts) | N |
| EF005025 | Min. rated voltage | N |
| EF005094 | MPP-voltage | N |
| EF005095 | Rated MPP-voltage | R |
| EF005096 | MPP-current | N |
| EF005117 | Nominal test voltage 100 V | L |
| EF005118 | Nominal test voltage 1000 V | L |
| EF005119 | Nominal test voltage 250 V | L |
| EF005120 | Nominal test voltage 2500 V | L |
| EF005121 | Nominal test voltage 500 V | L |
| EF005122 | Nominal test voltage 5000 V | L |
| EF005123 | Nominal test voltage adjustable | L |
| EF005125 | Nominal switching current at 230 V AC | N |
| EF005126 | Nominal switching current at 250 V AC | N |
| EF005127 | Nominal voltage | R |
| EF005138 | Emergency power supply integrated | L |
| EF005178 | Power over Ethernet | L |
| EF005229 | Switch capacity incandescent lamps | N |
| EF005230 | Switch capacity fluorescent lamp DUO | N |
| EF005231 | Switch capacity fluorescent lamp inductive | N |
| EF005232 | Switch capacity fluorescent lamp parallel | N |
| EF005233 | Switch capacity | R |
| EF005234 | Switching voltage | R |
| EF005290 | Voltage output 0 V ... 10 V | L |
| EF005291 | Voltage output 0 mV ... 100 mV | L |
| EF005293 | Voltage type (excitation voltage) | A |
| EF005294 | Voltage type (operating voltage) | A |
| EF005325 | Current surge function, number of channels | N |
| EF005387 | Power loss | N |
| EF005389 | Supply voltage AC | N |
| EF005390 | Supply voltage required | L |
| EF005426 | Resistance measurement | N |
| EF005502 | Connection voltage | R |
| EF005568 | Number of power current groups 25 A | N |
| EF005569 | Number of power current groups 63 A | N |
| EF005617 | Breaking capacity | N |
| EF005621 | Breaking capacity according to IEC 947, Icu, 400 V | N |
| EF005634 | Initial value measuring range (capacitive) | N |
| EF005719 | End value measuring range (inductive) | N |
| EF005732 | Frequency auxiliary voltage | N |
| EF005735 | Frequency input voltage | N |
| EF005736 | Frequency measuring voltage | N |
| EF005737 | Frequency rated current | N |
| EF005900 | Auxiliary voltage (AC) | R |
| EF005901 | Auxiliary voltage (DC) | R |
| EF005943 | Cooker group | A |
| EF005944 | Cooker group suitable as power current group | L |
| EF005984 | Max. secondary voltage | N |
| EF006001 | Measuring voltage | N |
| EF006064 | Rated short-circuit breaking capacity according to EN 60898 | N |
| EF006065 | Rated short-circuit breaking capacity according to IEC 60947-2 | N |
| EF006069 | Rated operation current Ie at AC-1 | N |
| EF006070 | Rated operation current Ie at AC-3 | N |
| EF006071 | Rated permanent current contacts | N |
| EF006074 | Nominal measuring voltage | N |
| EF006078 | Nominal voltage AC 50 Hz | N |
| EF006087 | Secondary nominal current | N |
| EF006125 | Primary voltage 1 | R |
| EF006126 | Primary voltage 2 | R |
| EF006127 | Primary voltage 3 | R |
| EF006134 | Voltage measuring range 1 | R |
| EF006135 | Voltage measuring range 2 | R |
| EF006136 | Voltage control | L |
| EF006138 | Coil voltage | N |
| EF006144 | Control voltage | R |
| EF006154 | Primary current | N |
| EF006239 | Total number of groups | N |
| EF006240 | Total number of poles (without ground contact) | N |
| EF006334 | Nominal voltage 1 | N |
| EF006335 | Nominal voltage 2 | N |
| EF006342 | Max. input power electric heating | N |
| EF006522 | Supply voltage lamp | N |
| EF006613 | Output current | R |
| EF006631 | Suitable for lamp power (1 lamp) | R |
| EF006632 | Suitable for lamp power (2 lamps) | R |
| EF006633 | Suitable for lamp power (3 lamps) | R |
| EF006634 | Suitable for lamp power (4 lamps) | R |
| EF006705 | Frequency input voltage | R |
| EF006706 | Rated switch current | N |
| EF006707 | Push button glow-lamp current | N |
| EF006711 | Monitoring voltage | A |
| EF006726 | Voltage according to EN 60309-2 | A |
| EF006733 | Voltage supply over bus | L |
| EF006780 | Mains voltage | R |
| EF006781 | Rated operation current Ie | R |
| EF006783 | Mains frequency | A |
| EF006785 | Overvoltage category | A |
| EF006790 | Output voltage AC | N |
| EF006792 | 1st secondary output voltage | R |
| EF006793 | 1st secondary output voltage AC | R |
| EF006794 | 1st secondary output voltage DC | R |
| EF006797 | 2nd secondary output voltage | R |
| EF006798 | 2nd secondary output voltage AC | R |
| EF006799 | 2nd secondary output voltage DC | R |
| EF006800 | 3rd secondary output voltage | R |
| EF006801 | 3rd secondary output voltage AC | R |
| EF006802 | 3rd secondary output voltage DC | R |
| EF006999 | Output voltage AC 50 Hz | R |
| EF007000 | Output voltage AC 60 Hz | R |
| EF007001 | Output voltage DC | R |
| EF007002 | Secondary voltage adjustable | L |
| EF007025 | Rated operation power at AC-3, 230 V | N |
| EF007026 | Rated operation power at DC-3 / DC-5 at 440 V | N |
| EF007027 | Rated operation power at AC-23, 400 V | N |
| EF007029 | Rated voltage Ue at AC 50 Hz | R |
| EF007030 | Rated voltage Ue at AC 60 Hz | R |
| EF007031 | Rated voltage Ue at DC | R |
| EF007033 | Rated operation current Ie at AC-15, 600 V | N |
| EF007035 | Rated operation current Ie at DC-3 / DC-5 at 440 V | N |
| EF007039 | Rated operation current Ie at 40 °C Tu | N |
| EF007040 | Rated operation current Ie at AC12, 125 V | N |
| EF007041 | Rated operation current Ie at AC12, 220 V | N |
| EF007042 | Rated operation current Ie at AC12, 24 V | N |
| EF007043 | Rated operation current Ie at DC-12, 24 V | N |
| EF007044 | Rated reactive power at 400 V, 50 Hz | N |
| EF007048 | Rated short-circuit breaking capacity Icu at 400 V, 50 Hz | N |
| EF007049 | Rated short-circuit breaking capacity Icu at 400 V, AC | N |
| EF007050 | Rated short-time withstand current lcw | N |
| EF007051 | Rated power | N |
| EF007053 | Rated power three-phase motor, inline, at 230 V | N |
| EF007054 | Rated power three-phase motor, inline, at 400 V | N |
| EF007055 | Rated power three-phase motor, inside delta, at 230 V | N |
| EF007056 | Rated power three-phase motor, inside delta, at 400 V | N |
| EF007065 | Rated voltage AC 50 Hz | R |
| EF007066 | Rated voltage AC 60 Hz | R |
| EF007067 | Rated voltage DC | R |
| EF007068 | Rated control supply voltage magnet drive AC 50 Hz | R |
| EF007069 | Rated control supply voltage magnet drive AC 60 Hz | R |
| EF007070 | Rated control supply voltage magnet drive DC | R |
| EF007075 | Rated supply voltage AC | R |
| EF007076 | Rated supply voltage AC 50 Hz | R |
| EF007077 | Rated supply voltage AC 60 Hz | R |
| EF007078 | Rated supply voltage DC | R |
| EF007082 | Rated operation current Ie at AC-15, 125 V | N |
| EF007084 | Rated operation current Ie at AC-15, 24 V | N |
| EF007085 | Rated operation current Ie at DC-13, 125 V | N |
| EF007087 | Rated operation current Ie at DC-13, 24 V | N |
| EF007118 | Input voltage AC 50 Hz | R |
| EF007119 | Input voltage AC 60 Hz | R |
| EF007120 | Input voltage DC | R |
| EF007121 | Primary voltage AC | R |
| EF007122 | Primary voltage tolerance | N |
| EF007129 | Adjustment range short-term delayed short-circuit release | R |
| EF007131 | Adjustment range undelayed short-circuit release | R |
| EF007157 | Contains power supply | L |
| EF007169 | Filter bank performance | N |
| EF007225 | Galvanic separation between supply voltage and all other current circuits | L |
| EF007351 | Max. output current AC 50 Hz | N |
| EF007352 | Max. output current AC 60 Hz | N |
| EF007353 | Max. output current DC | N |
| EF007355 | Max. rated operation voltage Ue AC | N |
| EF007356 | Max. rated operation current Ie | N |
| EF007357 | Max. rated operation voltage Ue | N |
| EF007358 | Max. rated current (Ith) at rated voltage AC | N |
| EF007359 | Max. rated current (Ith) at rated voltage DC | N |
| EF007360 | Max. input current AC 50 Hz | N |
| EF007361 | Max. input current AC 60 Hz | N |
| EF007362 | Max. input current DC | N |
| EF007368 | Max. rated current of one contact | N |
| EF007374 | Min. permitted supply voltage | N |
| EF007405 | Rated primary current | N |
| EF007409 | Primary voltage 10 | R |
| EF007410 | Primary voltage 4 | R |
| EF007411 | Primary voltage 5 | R |
| EF007412 | Primary voltage 6 | R |
| EF007413 | Primary voltage 7 | R |
| EF007414 | Primary voltage 8 | R |
| EF007415 | Primary voltage 9 | R |
| EF007452 | Relative short circuit voltage | N |
| EF007453 | Relative symmetric net voltage tolerance | N |
| EF007470 | Rated secondary apparent power | N |
| EF007471 | Rated secondary current | N |
| EF007472 | Secondary voltage 1 | R |
| EF007473 | Secondary voltage 10 | R |
| EF007474 | Secondary voltage 2 | R |
| EF007475 | Secondary voltage 3 | R |
| EF007476 | Secondary voltage 4 | R |
| EF007477 | Secondary voltage 5 | R |
| EF007478 | Secondary voltage 6 | R |
| EF007479 | Secondary voltage 7 | R |
| EF007480 | Secondary voltage 8 | R |
| EF007481 | Secondary voltage 9 | R |
| EF007500 | Rated current AC | R |
| EF007511 | Overcurrent limiting factor | A |
| EF007532 | Supply voltage AC 50 Hz | R |
| EF007533 | Supply voltage AC 60 Hz | R |
| EF007534 | Supply voltage DC | R |
| EF007553 | Permitted voltage at output | R |
| EF007554 | Permitted voltage at input | R |
| EF007679 | Rated operation current | N |
| EF007680 | Rated switch current auxiliary device | N |
| EF007681 | Rated voltage | A |
| EF007682 | Rated voltage AC | N |
| EF007683 | Rated voltage auxiliary device | N |
| EF007684 | Rated current AC 50 Hz | N |
| EF007685 | Rated current rail system | N |
| EF007688 | Operating current | N |
| EF007698 | Lightning current load-bearing capacity | N |
| EF007725 | Continuous voltage AC | N |
| EF007768 | Interference voltage | N |
| EF007848 | Main switch rated current | N |
| EF007900 | Lamp wattage main lamp | N |
| EF007901 | Lamp wattage auxiliary lamp | N |
| EF007926 | Max. rated current | N |
| EF007995 | Nominal voltage high value | N |
| EF007996 | Nominal voltage low value | N |
| EF008049 | Voltage protection level core/signal ground | N |
| EF008050 | Voltage protection level signal ground/protective ground | N |
| EF008071 | Control voltage type auxiliary equipment | A |
| EF008170 | Control voltage DC | N |
| EF008188 | End value adjustment range undelayed short-circuit release | N |
| EF008193 | Response value voltage | R |
| EF008197 | Initial value measuring range voltage | N |
| EF008198 | Initial value measuring range current | N |
| EF008202 | Response value impedance 1 | R |
| EF008203 | Response value impedance 2 | R |
| EF008204 | Response value amperage 1 | R |
| EF008205 | Response value amperage 2 | R |
| EF008206 | Operating voltage AC 50 Hz | R |
| EF008207 | Operating voltage AC 60 Hz | R |
| EF008208 | Operating voltage DC | R |
| EF008211 | Adjustable current range | R |
| EF008222 | Type of output voltage | A |
| EF008242 | Voltage type for actuating | A |
| EF008250 | Rated current In | N |
| EF008258 | Max. apparent power | N |
| EF008259 | Max. power on-delay time | N |
| EF008265 | End value measuring range voltage | N |
| EF008266 | End value measuring range current | N |
| EF008268 | Secondary rated current In | N |
| EF008284 | Max. output current 1 | N |
| EF008285 | Max. output current 2 | N |
| EF008286 | Max. output current 3 | N |
| EF008319 | Lamp power per meter | N |
| EF008409 | Rated excitation voltage | R |
| EF008481 | Rated operation current Ie at AC-15, 400 V | N |
| EF008482 | Reduction reactive power | R |
| EF008485 | Reduction apparent power | R |
| EF008486 | Reduction line voltage | N |
| EF008495 | Rated operation current Ie at AC-4, 400 V | N |
| EF008496 | Rated operation power at AC-4, 400 V | N |
| EF008533 | For nominal voltage up to | N |
| EF008536 | For dielectric strength up to | N |
| EF008559 | Max. short circuit current | N |
| EF008704 | Transmitting power | N |
| EF008729 | Suitable for max. number of poles main contact unit (total) | N |
| EF008730 | Suitable for max. current main contact unit | N |
| EF008776 | Current supply primary | A |
| EF008777 | With voltage indication | L |
| EF008791 | Resistance Rm | N |
| EF008792 | Resistance Re | N |
| EF008795 | Max. PV-voltage | N |
| EF008796 | Voltage protection level N-PE | N |
| EF008798 | Nominal voltage AC | R |
| EF008799 | Nominal voltage DC | R |
| EF008856 | Lamp voltage | R |
| EF008864 | Rated apparent power | N |
| EF008871 | Nominal voltage (Un) N-L | R |
| EF008872 | Nominal voltage (Un) L-L | R |
| EF008873 | Nominal current (In) | N |
| EF008961 | Max. current (Imax) per diode | N |
| EF008962 | Max. operating voltage (Umax) | N |
| EF009165 | Rated permanent current at AC-21, 400 V | N |
| EF009166 | Switching power at 400 V | N |
| EF009225 | Nominal input voltage | N |
| EF009226 | Nominal input current inverter | N |
| EF009227 | Nominal input current generator | N |
| EF009228 | Nominal input current shore | N |
| EF009245 | Starting current ratio | N |
| EF009248 | Voltage anti-condensation heater | N |
| EF009258 | With built-in USB power supply | L |
| EF009274 | Number of phases secondary | N |
| EF009275 | Number of phases primary | N |
| EF009300 | Max. power per charging point | N |
| EF009315 | Loading current | N |
| EF009326 | Max. nominal current | N |
| EF009345 | Nominal current | R |
| EF009347 | Max. system power | N |
| EF009393 | Nominal value output voltage 1 | N |
| EF009394 | Nominal value output voltage 2 | N |
| EF009395 | Nominal value output voltage 3 | N |
| EF009396 | Nominal value output current 1 | N |
| EF009397 | Nominal value output current 2 | N |
| EF009398 | Nominal value output current 3 | N |
| EF009404 | Max. voltage distortion output (linear load) | N |
| EF009405 | Output power factor | N |
| EF009413 | Number of cores signal-/telecommunications cable | N |
| EF009417 | Number of cores low voltage power cable | N |
| EF009435 | Type voltage pump (system pump) | A |
| EF009439 | Limitation max. electric power consumption | N |
| EF009471 | Suitable for constant current | L |
| EF009472 | Suitable for constant voltage | L |
| EF009473 | Suitable for DC-voltage (primary side) | L |
| EF009474 | Operating current | R |
| EF009488 | Rated operation current Ie at AC-51 | N |
| EF009489 | Rated operation current Ie at AC-53a | N |
| EF009495 | Integrated power-supply for cameras | L |
| EF009510 | Reverse current load | N |
| EF009511 | With alternating-current converter | L |
| EF009555 | Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V | N |
| EF009556 | Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V | N |
| EF009557 | Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V | N |
| EF009558 | Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V | N |
| EF009560 | Max. output voltage | N |
| EF009561 | Nominal output current I2N | N |
| EF009599 | Rated operation power at AC-3, 230 V, 3-phase | N |
| EF009600 | Rated power, 460 V, 60 Hz, 3-phase | N |
| EF009601 | Rated power, 575 V, 60 Hz, 3-phase | N |
| EF009602 | Rated operation current at AC-3, 400 V | N |
| EF009605 | Rated conditional short-circuit current, type 2, 400 V | N |
| EF009606 | Rated conditional short-circuit current, type 2, 230 V | N |
| EF009607 | Rated conditional short-circuit current, type 1, 480 Y/277 V | N |
| EF009608 | Rated conditional short-circuit current, type 1, 600 Y/347 V | N |
| EF009632 | Prospective short-circuit current | R |
| EF009636 | Max. rated voltage | N |
| EF009643 | Voltage protection level (DC+ - DC-) | N |
| EF009644 | Voltage protection level (DC+/DC- - PE) | N |
| EF009694 | Rated current to luminaire | N |
| EF009714 | Power over Ethernet (PoE) | A |
| EF009716 | Max. PoE power | N |
| EF009765 | Rated operation current Ie at AC-53b | N |
| EF009781 | Output voltage for heating power | N |
| EF009782 | Output current for heating power | N |
| EF009785 | Output voltage for fans | N |
| EF009790 | Relative accuracy of measurement voltage | N |
| EF009791 | Relative accuracy of measurement current | N |
| EF009792 | Supply voltage DC | N |
| EF009793 | Input voltage per DC input | R |
| EF009794 | Input current per DC input | R |
| EF009841 | Battery powered | L |
| EF009850 | Nominal test voltage adjustable with ramp function | L |
| EF009856 | Nominal test voltage 10 V | L |
| EF009857 | Nominal test voltage 50 V | L |
| EF009864 | Max. voltage measuring circuit category | N |
| EF009865 | Voltage output 0 V ... +/- 300 mV | L |
| EF009866 | Voltage output 0 V ... 3 V | L |
| EF009867 | Voltage output 0 V ... 15 V | L |
| EF009868 | Lowest resolution voltage output | A |
| EF009869 | Lowest resolution current output | A |
| EF009870 | Power sink (transmitter simulator) 0 mA ... 24 mA | L |
| EF009871 | Lowest resolution power sink | A |
| EF009873 | Max. resistance encoder | N |
| EF009898 | Output apparent power | N |
| EF009961 | Capacity 15h | N |
| EF010779 | Pump power consumption (solpump) | N |
| EF010780 | Pump power consumption standby (solstandbypump) | N |
| EF010794 | Standby power consumption (solstandby) | N |
| EF010897 | Supplementary electricity consumption at full load (ELmax) | N |
| EF010913 | Standby heat loss (Pstby) | N |
| EF011586 | Lamp power | R |
| EF011635 | Power consumption in operation | N |
| EF011678 | Min. dry lightning impulse withstand voltage | N |
| EF011679 | Wet power frequency withstand voltage | N |
| EF011700 | Rated voltage U0/U (Um) | A |
| EF011756 | Nominal current according to EN 50180/EN 50181 | A |
| EF011762 | No-load loss | N |
| EF011777 | Rated permanent current at AC-23, 400 V | N |
| EF011919 | Continuous heating power at 10 °C | N |
| EF011922 | Active current limitation x IN | N |
| EF011924 | Fail safe element | N |
| EF011926 | Max. capacitive load | N |
| EF011931 | Connected load heating element | R |
| EF011932 | Connected load ventilator | R |
| EF011955 | Resistance measuring range | R |
| EF011960 | Rated operation power NEMA | N |
| EF011980 | Rated impulse withstand voltage Uimp | N |
| EF011981 | Rated short-circuit breaking capacity Icn according to EN 61009-1 | N |
| EF011992 | Min. starting current | N |
| EF012122 | Lamp power per foot | N |
| EF012270 | Rated impulse sparkover voltage | N |
| EF012271 | Rated power-frequency withstand voltage | N |
| EF012273 | Lightning current load-bearing capacity (10/350 µs) | N |
| EF012274 | Max. discharge surge current (8/20) | N |
| EF012275 | Total discharge current (8/20) (L1+L2+L3+N-PE) | N |
| EF012276 | Voltage protection level L-PE | N |
| EF012279 | Total discharge current (8/20) | N |
| EF012280 | Continuous voltage DC | N |
| EF012281 | Rated voltage DC | N |
| EF012300 | Impedance | R |
| EF012331 | Power consumption in standby mode | N |
| EF012332 | Power consumption on off mode | N |
| EF012338 | Max. working voltage | N |
| EF012348 | Electrical connection rating | N |
| EF012355 | Effective sinus power per channel | N |
| EF012365 | Input voltage DC | A |
| EF012389 | Power loss at rated current | N |
| EF012424 | Motor power input (P1) per motor | N |
| EF012425 | Motor power output (P2) per motor | N |
| EF012483 | Usable battery capacity | N |
| EF012541 | Pick up current | N |
| EF012542 | Number of current pulses | N |
| EF012596 | Nominal battery capacity | N |
| EF012606 | Measuring range effective power | R |
| EF012607 | Measuring range apparent power | R |
| EF012623 | Transient discharge current (10/350 µs) | N |
| EF012624 | Transient discharge current (8/20 µs) | N |
| EF012625 | Temporary discharge current to 1 s (16.7 Hz, 50 Hz, 60 Hz) | N |
| EF012626 | Max. long-duration limiting voltage | N |
| EF012627 | Short-circuit breaking capacity (Isccr) | N |
| EF012628 | Rated short-circuit breaking capacity according to EN 61009 | N |
| EF012754 | Nominal power resistive load | R |
| EF012755 | Nominal power inductive load | R |
| EF012756 | Nominal power capacitive load | R |
| EF012768 | Max. output current charger | N |
| EF012769 | Max. output current alternator | N |
| EF013275 | Max. output current at 40 °C | N |
| EF013495 | Electricity consumption | R |
| EF013551 | Conductor resistance at 20 °C | N |
| EF013598 | String protection | A |
| EF013599 | Fuse size input | N |
| EF013620 | Max. unloading current | N |
| EF013722 | Load loss (secondary voltage 1) | N |
| EF013723 | Load loss (secondary voltage 2) | N |
| EF013736 | Load loss (secondary voltage 3) | N |
| EF013744 | Nominal test voltage 10 kV | L |
| EF013745 | Nominal test voltage 15 kV | L |
| EF013822 | Rated system voltage 12 V DC | L |
| EF013823 | Rated system voltage 24 V DC | L |
| EF013824 | Rated system voltage 48 V DC | L |
| EF013825 | Max. loading current at 40 °C | N |
| EF013841 | Connection voltage of open-keeping function | N |
| EF013942 | Frequency indoor unit | A |
| EF013943 | Number of phases indoor unit | N |
| EF013944 | Connection voltage indoor unit | N |
| EF013945 | Frequency outdoor unit | A |
| EF013946 | Number of phases outdoor unit | N |
| EF013947 | Connection voltage outdoor unit | N |
| EF014026 | DC measurement mV | R |
| EF014059 | Output signal amplitude | R |
| EF014234 | Brush motor power consumption | N |
| EF014235 | Suction nozzle power consumption | N |
| EF014246 | Drive engine power consumption | N |
| EF014352 | Power consumption water pump | N |
| EF014353 | Power consumption suction nozzle | N |
| EF014361 | Max. high frequency power | N |
| EF014362 | Max. ultrasonic power | N |
| EF014613 | Current of miniature circuit breaker (MCB) socket outlets | N |
| EF014648 | Test voltage | R |
| EF014649 | Test current | R |
| EF014710 | Rated system voltage 36 V DC | L |
| EF014711 | Rated system voltage 60 V DC | L |
| EF014712 | Rated system voltage 72 V DC | L |
| EF014805 | Cutting current | R |
| EF014807 | ED at max. cutting current | N |
| EF014808 | Cutting current at 35 % ED / 40 °C | N |
| EF014809 | Cutting current at 40 % ED / 40 °C | N |
| EF014810 | Cutting current at 60 % ED / 40 °C | N |
| EF014811 | Cutting current at 100 % ED / 40 °C | N |
| EF015127 | Voltage system | A |
| EF015154 | Power traction motor | N |
| EF015155 | Power lift motor | N |
| EF015325 | With electrical connection | L |
| EF015533 | Max. number of luminaires per miniature circuit breaker C16 (MCB) | N |
| EF015534 | Max. number of luminaires per miniature circuit breaker B16 (MCB) | N |
| EF015697 | With emergency power supply | L |
| EF015721 | Nominal input heat pump according to EN 16147 (7°C) | N |
| EF015722 | Nominal input heat pump according to EN 16147 (20 °C) | N |
| EF015723 | Power consumption in the standby period according to EN 16147 | N |
| EF015789 | Activation shunt trip | R |
| EF015790 | Activating undervoltage release | R |
| EF015813 | Rated current of monitored circuit | N |
| EF015814 | Rated voltage of monitored circuit | N |
| EF015818 | Residual operating current Idn DC | R |
| EF015819 | Residual operating current Idn AC | R |
| EF015820 | Frequency range residual operating current fidn type A | R |
| EF015821 | Frequency range residual operating current fidn type AC | R |
| EF015822 | Frequency range residual operating current fidn type B | R |
| EF015865 | Fuse construction type according to IEC 60269 | A |
| EF015870 | Max. input voltage DC | N |
| EF015871 | Max. input current DC per MPP tracker | N |
| EF015872 | Max. input current DC per string input | N |
| EF015873 | Type of USB power supply | A |
| EF015953 | Max. switching power LED | N |
| EF015962 | Max. overcurrent protection device, parallel connection (fuse) | N |
| EF015963 | Max. overcurrent protection device, series connection (fuse) | N |
| EF015999 | Insulation between 2 rungs | N |
| EF016001 | Integrated short-circuit protection selective to fuse gG | N |
| EF016003 | Voltage switching spark gap technology | L |
| EF016004 | Overcurrent protected voltage tapping | L |
| EF016009 | Insulation between 2 steps | N |
| EF016043 | Type of overvoltage protection device | A |
| EF016170 | Nominal current outdoor unit | N |
| EF016181 | Undervoltage protection (ANSI 27) | L |
| EF016188 | Phase-sequence-voltage supervision (ANSI 47) | L |
| EF016193 | Voltage dependent overcurrent protection (ANSI 51V) | L |
| EF016195 | Overvoltage protection (ANSI 59) | L |
| EF016196 | Overvoltage protection, zero-sequence system (ANSI 59N) | L |
| EF016240 | Max. charge power | N |
| EF016241 | Max. discharge power | N |
| EF016242 | Max. emergency power | N |
| EF016578 | Rated voltage Um | N |
| EF016707 | Max. current rating of USB power supply | N |
| EF016761 | Continuity measurement current | R |
| EF016763 | Open circuit voltage measurement Uoc | R |
| EF016764 | Short circuit current measurement Isc | R |
| EF016765 | Insulation resistance measurement voltage | R |
| EF016883 | Max. working voltage AC | N |
| EF016884 | Max. working voltage DC | N |
| EF017048 | Method of current voltage curve trace | A |
| EF017111 | Max. current measuring range with clip factor | N |
| EF017307 | Rated operating voltage AC | R |
| EF017308 | Rated operating voltage DC | R |
| EF017355 | Nominal value output voltage 4 | N |
| EF017356 | Nominal value output voltage 5 | N |
| EF017383 | Power connector type | A |
| EF017421 | Min. testable voltage | N |
| EF017424 | Alternator voltage measurement range | R |
| EF017425 | Battery voltage measurement range | R |
| EF017437 | Max. short circuit current per MPPT | N |
| EF017439 | Power consumption idle and standby | R |
| EF017440 | Max. input current per string | N |
| EF017554 | Rated current of phase/neutral current inputs | N |
| EF017588 | Max. excitation voltage | N |
| EF017589 | Max. excitation current | N |
| EF017592 | Threshold voltage | N |
| EF017599 | Power consumption at max. air volume at 100 Pa | N |
| EF017658 | Max. peak current | N |
| EF017659 | Internal arc withstand current | N |
| EF017670 | Rated capacitive current back-to-back | N |
| EF017676 | Fuse system according to IEC 60269 | A |
| EF017724 | Rated mainly active load-breaking current | N |
| EF017725 | Rated transfer current | N |
| EF017726 | Rated take-over current | N |
| EF017727 | Rated short-circuit making current | N |
| EF017728 | Rated peak withstand current | N |
| EF017730 | Rated normal current with fuses | N |
| EF017732 | Motor drive supply voltage (DC) | N |
| EF017733 | Motor drive supply voltage (AC) | N |
| EF017746 | Clip factors for current sensor | A |
| EF017747 | Clip factors for current transformer | A |
| EF017749 | Max. voltage measuring range AC/DC | N |
| EF017750 | Lowest resolution, AC/DC voltage | A |
| EF017751 | Max. current measuring range, AC/DC | N |
| EF017752 | Lowest resolution, AC/DC current | A |
| EF017753 | Short-circuit breaking capacity according to class E1 | N |
| EF017754 | Breaking capacity with fuses according to class E2 | N |
| EF017765 | Mechanical latch supply voltage (AC) | R |
| EF017766 | Mechanical latch supply voltage (DC) | R |
| EF017767 | Chopping current | R |
| EF017977 | Rated continuous thermal current | N |
| EF017979 | Rated dynamic current | N |
| EF017981 | Current accuracy class | A |
| EF017982 | Voltage accuracy class | A |
| EF017984 | Rated extended primary current factor | N |
| EF017986 | Rated primary voltage | N |
| EF018024 | Rated primary current of application | N |
| EF018025 | Rated primary voltage of application | N |
| EF018026 | Rated short-time thermal current for 1s | N |
| EF018027 | Rated short-time thermal current for 3s | N |
| EF018028 | Rated transformation ratio for current measurement (at 50Hz) | N |
| EF018029 | Rated transformation ratio for current measurement (at 60Hz) | N |
| EF018030 | Rated transformation ratio for voltage measurement | N |
| EF018063 | Max. voltage for equipment | N |
| EF018147 | CCA operating range according to SAE | R |
| EF018149 | CCA operating range according to IEC | R |
| EF018164 | Rated reactive power at 400 V, 60 Hz | N |
| EF018170 | Current setting undelayed short-circuit release | R |
| EF018171 | Current setting delayed short-circuit release | R |
| EF018394 | Breaking capacity at nominal voltage, AC | N |
| EF018395 | Breaking capacity at nominal voltage, DC | N |
| EF018420 | Power per IR lamp | N |
| EF018421 | Power per UV lamp | N |
| EF018517 | Continuous current Inc | N |
| EF018643 | Nominal output power AC | R |
| EF018759 | Nominal output power DC | N |
| EF018782 | Max. battery capacity | N |
| EF018918 | Emergency power supply system | A |
| EF018920 | Power consumption in emergency mode | N |
| EF018969 | Type of control fuse | A |
| EF019010 | Total lamp power | N |
| EF019088 | Mains surge immunity (differential mode, L-N) | N |
| EF019089 | Mains surge immunity (common mode, L/N-Ground) | N |
| EF019230 | Resistance per signal | N |
| EF019253 | Max. latch preload AC | N |
| EF019254 | Min. latch preload AC | N |
| EF019255 | Max. latch preload DC | N |
| EF019256 | Min. latch preload DC | N |
| EF019260 | Resistant to continuous current | R |
| EF019261 | Contact loading capacity monitoring contact | N |
| EF019321 | Nominal voltage (Un) | N |
| EF019323 | With primary wiring | L |
| EF019324 | Overvoltage protection | A |
| EF019348 | Max. usable input current | N |
| EF019351 | Nominal charging/discharging current | N |
| EF019390 | Battery capacity (C10 at 20 °C) | R |
| EF019404 | Voltage measuring range AC | R |
| EF019405 | Voltage measuring range DC | R |
| EF019441 | Max. number of luminaires per miniature circuit breaker C10 (MCB) | N |
| EF019499 | DC-system voltage (battery inverter) | N |
| EF019500 | Max. input power DC (battery inverter) | N |
| EF019501 | Max. input voltage DC (battery inverter) | N |
| EF019502 | Max. usable input current (battery inverter) | N |
| EF019503 | Max. input power DC (grid inverter) | N |
| EF019504 | Max. input voltage DC (grid inverter) | N |
| EF019505 | Max. input current DC (grid inverter) | N |
| EF019506 | Max. input current DC per MPP tracker (grid inverter) | N |
| EF019507 | Max. input current DC per string input (grid inverter) | N |
| EF019508 | Rated MPP-voltage (grid inverter) | N |
| EF020233 | Connection voltage | A |
| EF020286 | Max. contact voltage | N |
| EF020687 | Max. power per channel | N |
| EF020754 | Protected against overvoltage | L |
| EF021297 | Connection voltage of fans | N |
| EF021298 | Connection voltage of heating element(s) | N |
| EF021299 | Max. input power fans | N |
| EF021300 | Max. input current of fans | N |
| EF021301 | Max. input current of heater | N |
| EF021373 | Contact load | N |
| EF021414 | Electric power of system | N |
| EF022485 | Breakdown voltage | N |
| EF022541 | Max. contact load | N |
| EF022709 | Max. welding current | N |
| EF023037 | Max. electric power input | N |
| EF023970 | Supply voltage | A |
| EF024946 | Connection voltage (system) | N |
| EF024947 | Fuse (slow) | N |
| EF024948 | Cooling input power | R |
| EF024950 | Heating input power | R |
| EF025586 | Cold crank amps according to EN | N |
| EF025587 | Cold crank amps according to SAE | N |
| EF025588 | Capacity 20h | N |
| EF025739 | Recommended battery capacity | R |
| EF025740 | Power factor | N |
| EF025763 | Max. load capacity at 35 % (SMAW) | N |
| EF025764 | Max. load capacity at 40 % (SMAW) | N |
| EF025765 | Max. load capacity at 60 % (SMAW) | N |
| EF025766 | Max. load capacity at 100 % (SMAW) | N |
| EF025767 | Max. load capacity at 35 % (GTAW) | N |
| EF025768 | Max. load capacity at 40 % (GTAW) | N |
| EF025769 | Max. load capacity at 60 % (GTAW) | N |
| EF025770 | Max. load capacity at 100 % (GTAW) | N |
| EF025771 | Open circuit voltage (VRD) | N |
| EF025772 | Welding current (SMAW) | R |
| EF025773 | Welding voltage (SMAW) | R |
| EF025774 | Welding current (GTAW) | R |
| EF025775 | Welding voltage (GTAW) | R |
| EF025777 | Max. load capacity at 35 % (GMAW) | N |
| EF025778 | Max. load capacity at 40 % (GMAW) | N |
| EF025779 | Max. load capacity at 60 % (GMAW) | N |
| EF025780 | Max. load capacity at 100 % (GMAW) | N |
| EF025781 | Welding current (GMAW) | N |
| EF025782 | Welding voltage (GMAW) | N |
| EF025785 | Max. load capacity (CO2) | N |
| EF025786 | Max. load capacity (Mixed gas) | N |
| EF025788 | Max. load capacity (DC) | N |
| EF025789 | Max. load capacity (AC) | N |
| EF025850 | Power electric heating element | R |
| EF025982 | Suitable for engine power | R |
| EF026135 | Nominal voltage DC inverter | N |
| EF026136 | Continuous power inverter | N |
| EF026137 | Nominal output voltage inverter | N |
| EF026138 | Nominal input voltage charger | N |
| EF026207 | Nominal input voltage 1 | N |
| EF026208 | Nominal input voltage 2 | N |
| EFAT0001 | Rated current of overload protection device with standard pin acc. to OVE R 21 | N |
| EFAT0002 | Rated current of overload protection device with system pin acc. to OVE R 21 | N |