EC001821 versión 7

Diffuse reflective photoelectric sensor

Publicada en
ETIM-10.0
También se llama
Light curtain, Light scanner, energetic, Light sensor, Push button

Performance (3)

#FeatureTipoUnidadValores permitidos
1
Operating distance
Rmm—
46
Response time
Nms—
47
Transmission range of the safety field
Nm—

Options (1)

#FeatureTipoUnidadValores permitidos
2
Pre failure notice
L——

Model/type (10)

#FeatureTipoUnidadValores permitidos
3
With time function
L——
6
With reflector
L——
11
With other analogue output
L——
31
Type of switching output
A—
32
Type of switch function
A—
36
Construction type housing
A—
49
Type of safety according to IEC 61496-1
A—
52
With monitoring function downstream switching devices
L——
55
Type of light
A—
59
With restart blockage
L——

Other (7)

#FeatureTipoUnidadValores permitidos
4
Max. switching distance
Nmm—
12
Setting procedure
A—
41
Sensing mode
A—
45
Min. reflector distance
Nmm—
48
Switching frequency
NHz—
54
Wavelength of the sensor
Nnm—
56
Light dot
Nmm²—

Electrical (7)

#FeatureTipoUnidadValores permitidos
5
Max. output current
NmA—
44
Max. output current at protected output
NmA—
50
Switching voltage of OSSD at state "high"
NV—
51
Voltage type
A—
64
Rated control supply voltage AC 50 Hz
RV—
65
Rated control supply voltage AC 60 Hz
RV—
66
Rated control supply voltage DC
RV—

Connection (10)

#FeatureTipoUnidadValores permitidos
7
Analogue output 0 V ... 10 V
L——
8
Analogue output 0 mA ... 20 mA
L——
9
Analogue output 4 mA ... 20 mA
L——
10
Analogue output -10 V ... +10 V
L——
25
Number of semiconductor outputs with signalling function
N——
26
Number of contact energized outputs with signalling function
N——
27
Number of protected semiconductor outputs
N——
28
Number of protected contact energized outputs
N——
30
Type of electric connection
A—
57
AWG-number
N——

Communication (13)

#FeatureTipoUnidadValores permitidos
13
With communication interface analogue
L——
14
With communication interface AS-Interface
L——
15
With communication interface CANOpen
L——
16
With communication interface DeviceNet
L——
17
With communication interface Ethernet
L——
18
With communication interface INTERBUS
L——
19
With communication interface PROFIBUS
L——
20
With communication interface RS-232
L——
21
With communication interface RS-422
L——
22
With communication interface RS-485
L——
23
With communication interface SSD
L——
24
With communication interface SSI
L——
29
Type of interface for safety communication
A—

Measurements (4)

#FeatureTipoUnidadValores permitidos
37
Width sensor
Nmm—
38
Diameter sensor
Nmm—
39
Height of sensor
Nmm—
40
Length of sensor
Nmm—

Material (3)

#FeatureTipoUnidadValores permitidos
42
Material of optical surface
A—
43
Housing material
A—
58
Material of cable sheath
A—

Application (1)

#FeatureTipoUnidadValores permitidos
60
Suitable for safety functions
L——

Operating conditions (1)

#FeatureTipoUnidadValores permitidos
63
Ambient temperature
R°C—