EC002721 versió 7

Optical frame sensor

Publicada a
ETIM-10.0
També s'anomena
Light curtain

Measurements (7)

#FeatureTipusUnitatValors permesos
1
Min. object size
Nmm—
2
Frame opening lengthwise
Nmm—
3
Frame opening cross
Nmm—
39
Width sensor
Nmm—
40
Diameter sensor
Nmm—
41
Height of sensor
Nmm—
42
Length of sensor
Nmm—

Other (8)

#FeatureTipusUnitatValors permesos
4
Rated switching distance
Nmm—
5
Max. switching distance
Nmm—
14
Setting procedure
A—
43
Sensing mode
A—
47
Min. reflector distance
Nmm—
51
Switching frequency
NHz—
61
Wavelength of the sensor
Nnm—
63
Light dot
Nmm²—

Electrical (7)

#FeatureTipusUnitatValors permesos
6
Max. output current
NmA—
46
Max. output current at protected output
NmA—
53
Switching voltage of OSSD at state "high"
NV—
54
Rated control supply voltage AC 50 Hz
RV—
55
Rated control supply voltage AC 60 Hz
RV—
56
Rated control supply voltage DC
RV—
57
Voltage type
A—

Model/type (10)

#FeatureTipusUnitatValors permesos
7
With time function
L——
8
With reflector
L——
13
With other analogue output
L——
33
Type of switching output
A—
34
Type of switch function
A—
38
Construction type housing
A—
52
Type of safety according to IEC 61496-1
A—
58
With monitoring function downstream switching devices
L——
62
Type of light
A—
66
With restart blockage
L——

Connection (10)

#FeatureTipusUnitatValors permesos
9
Analogue output 0 V ... 10 V
L——
10
Analogue output 0 mA ... 20 mA
L——
11
Analogue output 4 mA ... 20 mA
L——
12
Analogue output -10 V ... +10 V
L——
27
Number of semiconductor outputs with signalling function
N——
28
Number of contact energized outputs with signalling function
N——
29
Number of protected semiconductor outputs
N——
30
Number of protected contact energized outputs
N——
32
Type of electric connection
A—
64
AWG-number
N——

Communication (13)

#FeatureTipusUnitatValors permesos
15
With communication interface analogue
L——
16
With communication interface AS-Interface
L——
17
With communication interface CANOpen
L——
18
With communication interface DeviceNet
L——
19
With communication interface Ethernet
L——
20
With communication interface INTERBUS
L——
21
With communication interface PROFIBUS
L——
22
With communication interface RS-232
L——
23
With communication interface RS-422
L——
24
With communication interface RS-485
L——
25
With communication interface SSD
L——
26
With communication interface SSI
L——
31
Type of interface for safety communication
A—

Material (3)

#FeatureTipusUnitatValors permesos
44
Material of optical surface
A—
45
Housing material
A—
65
Material of cable sheath
A—

Operating conditions (1)

#FeatureTipusUnitatValors permesos
48
Ambient temperature
R°C—

Performance (2)

#FeatureTipusUnitatValors permesos
49
Response time
Nms—
50
Transmission range of the safety field
Nm—

Options (1)

#FeatureTipusUnitatValors permesos
59
Pre failure notice
L——

Application (1)

#FeatureTipusUnitatValors permesos
67
Suitable for safety functions
L——