EC002927 versió 4
Wind generator
- Publicada a
- ETIM-10.0
- També s'anomena
- Wind power plant, Wind power station, Wind turbine
Petició equivalent
curl -X POST '<origen>/api/v2/Class/Details' \
-H 'Content-Type: application/json' \
-d '{"code":"EC002927","version":4,"languagecode":"EN","include":{"descriptions":true,"translations":true,"fields":["Group","Features","Releases"]}}'Resposta de Class/Details
{
"code": "EC002927",
"version": 4,
"status": 5,
"modelling": false,
"descriptionEn": "Wind generator",
"description": "Wind generator",
"synonyms": [
"Wind generator",
"Wind power plant",
"Wind power station",
"Wind turbine"
],
"group": {
"code": "EG000055",
"descriptionEn": "Photovoltaics, wind energy",
"description": "Photovoltaics, wind energy",
"translations": [
{
"languagecode": "EN",
"description": "Photovoltaics, wind energy"
}
]
},
"features": [
{
"orderNumber": 1,
"values": [
{
"orderNumber": 1,
"code": "EV011678",
"description": "Darrieus rotor",
"descriptionEn": "Darrieus rotor",
"translations": [
{
"languagecode": "EN",
"description": "Darrieus rotor"
}
]
},
{
"orderNumber": 2,
"code": "EV011679",
"description": "Downwind rotor",
"descriptionEn": "Downwind rotor",
"translations": [
{
"languagecode": "EN",
"description": "Downwind rotor"
}
]
},
{
"orderNumber": 3,
"code": "EV011680",
"description": "Upwind rotor",
"descriptionEn": "Upwind rotor",
"translations": [
{
"languagecode": "EN",
"description": "Upwind rotor"
}
]
},
{
"orderNumber": 4,
"code": "EV000154",
"description": "Other",
"descriptionEn": "Other",
"translations": [
{
"languagecode": "EN",
"description": "Other"
}
]
}
],
"portcode": 0,
"featureGroupCode": "EFG00012",
"code": "EF009502",
"type": "Alphanumeric",
"local": false,
"description": "Type of rotor",
"descriptionEn": "Type of rotor",
"translations": [
{
"languagecode": "EN",
"description": "Type of rotor"
}
]
},
{
"orderNumber": 2,
"portcode": 0,
"featureGroupCode": "EFG00012",
"code": "EF009503",
"type": "Numeric",
"local": false,
"description": "Number of rotor blades",
"descriptionEn": "Number of rotor blades",
"translations": [
{
"languagecode": "EN",
"description": "Number of rotor blades"
}
]
},
{
"orderNumber": 3,
"unit": {
"code": "EU570376",
"description": "Metre per second",
"descriptionEn": "Metre per second",
"abbreviation": "m/s",
"abbreviationEn": "m/s",
"translations": [
{
"abbreviation": "m/s",
"languagecode": "EN",
"description": "Metre per second"
}
]
},
"portcode": 0,
"featureGroupCode": "EFG00017",
"code": "EF009504",
"type": "Numeric",
"local": false,
"description": "Engaging wind speed",
"descriptionEn": "Engaging wind speed",
"translations": [
{
"languagecode": "EN",
"description": "Engaging wind speed"
}
]
},
{
"orderNumber": 4,
"unit": {
"code": "EU570376",
"description": "Metre per second",
"descriptionEn": "Metre per second",
"abbreviation": "m/s",
"abbreviationEn": "m/s",
"translations": [
{
"abbreviation": "m/s",
"languagecode": "EN",
"description": "Metre per second"
}
]
},
"portcode": 0,
"featureGroupCode": "EFG00017",
"code": "EF009505",
"type": "Numeric",
"local": false,
"description": "Shutdown wind speed",
"descriptionEn": "Shutdown wind speed",
"translations": [
{
"languagecode": "EN",
"description": "Shutdown wind speed"
}
]
},
{
"orderNumber": 5,
"unit": {
"code": "EU570418",
"description": "Kilowatt",
"descriptionEn": "Kilowatt",
"abbreviation": "kW",
"abbreviationEn": "kW",
"translations": [
{
"abbreviation": "kW",
"languagecode": "EN",
"description": "Kilowatt"
}
]
},
"portcode": 0,
"featureGroupCode": "EFG00017",
"code": "EF000169",
"type": "Numeric",
"local": false,
"description": "Nominal power",
"descriptionEn": "Nominal power",
"translations": [
{
"languagecode": "EN",
"description": "Nominal power"
}
]
},
{
"orderNumber": 6,
"unit": {
"code": "EU570079",
"description": "Volt",
"descriptionEn": "Volt",
"abbreviation": "V",
"abbreviationEn": "V",
"translations": [
{
"abbreviation": "V",
"languagecode": "EN",
"description": "Volt"
}
]
},
"portcode": 0,
"featureGroupCode": "EFG00007",
"code": "EF005127",
"type": "Range",
"local": false,
"description": "Nominal voltage",
"descriptionEn": "Nominal voltage",
"translations": [
{
"languagecode": "EN",
"description": "Nominal voltage"
}
]
},
{
"orderNumber": 7,
"unit": {
"code": "EU570036",
"description": "Metre",
"descriptionEn": "Metre",
"abbreviation": "m",
"abbreviationEn": "m",
"translations": [
{
"abbreviation": "m",
"languagecode": "EN",
"description": "Metre"
}
]
},
"portcode": 0,
"featureGroupCode": "EFG00011",
"code": "EF001643",
"type": "Numeric",
"local": false,
"description": "Diameter impeller",
"descriptionEn": "Diameter impeller",
"translations": [
{
"languagecode": "EN",
"description": "Diameter impeller"
}
]
},
{
"orderNumber": 8,
"unit": {
"code": "EU570036",
"description": "Metre",
"descriptionEn": "Metre",
"abbreviation": "m",
"abbreviationEn": "m",
"translations": [
{
"abbreviation": "m",
"languagecode": "EN",
"description": "Metre"
}
]
},
"portcode": 0,
"featureGroupCode": "EFG00011",
"code": "EF007989",
"type": "Numeric",
"local": false,
"description": "Nominal height",
"descriptionEn": "Nominal height",
"translations": [
{
"languagecode": "EN",
"description": "Nominal height"
}
]
}
],
"releases": [
"ETIM-10.0"
],
"translations": [
{
"synonyms": [
"Wind generator",
"Wind power plant",
"Wind power station",
"Wind turbine"
],
"languagecode": "EN",
"description": "Wind generator"
}
]
}