EC010198 versió 6
Boiler with preburner
- Publicada a
- ETIM-10.0
- També s'anomena
- —
Diferències de la versió 6 amb l'anterior, segons els codis de canvi que publica ETIM. La classe hi consta com a Canviada: 5 features noves, 38 canviades, 12 tretes i 28 canvis en valors permesos.
| # | Feature | Tipus | Unitat | Valors permesos |
|---|---|---|---|---|
| 17 | EF018617Nova Gas pre-pressure | R | mbar | — |
| 18 | EF015358Nova Oil pressure | R | mbar | — |
| 19 | EF023847Canviada Control signal on/off | L | — | — |
| 20 | EF023848Canviada Control signal high/low | L | — | — |
| 21 | EF023849Canviada Control signal 0-10 V | L | — | — |
| 22 | EF022183Canviada Burner controller high/low | L | — | — |
| 23 | EF022184Canviada Modulating burner control | L | — | — |
| 24 | EF003625Canviada Connection voltage | N | V | — |
| 25 | EF005870Canviada Closed version | L | — | — |
| 26 | EF020354Canviada Flame protection device | A | — | |
| 27 | EF021384Canviada Oil preheater | L | — | — |
| 28 | EF021381Canviada Built-in operating hours counter | L | — | — |
| 29 | EF020448Canviada Max. supply temperature (operating temperature) | N | °C | — |
| 30 | EF020089Canviada Min. return temperature | N | °C | — |
| 31 | EF025498Nova Operating pressure | R | bar | — |
| 32 | EF023846Canviada Second return connection | L | — | — |
| 33 | EF020098Canviada Water-side resistance at dT 20 °C | N | kPa | — |
| 34 | EF000040Canviada Height | N | mm | — |
| 35 | EF000008Canviada Width | N | mm | — |
| 36 | EF000049Canviada Depth | N | mm | — |
| 37 | EF002286Canviada Connection supply | A | — | |
| 38 | EF023886Canviada Nominal diameter of supply | A | — | |
| 39 | EF020469Canviada Outer pipe diameter supply | N | mm | — |
| 40 | EF002287Canviada Connection return | A | — | |
| 41 | EF023887Canviada Nominal diameter return | A | — | |
| 42 | EF020475Canviada Outer pipe diameter return | N | mm | — |
| 43 | EF020481Canviada Fuel connection | A | — | |
| 44 | EF023888Canviada Nominal diameter fuel | A | — | |
| 45 | EF020482Canviada Outer pipe diameter fuel | N | mm | — |
| 46 | EF020488Canviada Air supply connection | A | — | |
| 47 | EF020489Canviada Nominal duct width, air supply | N | mm | — |
| 48 | EF020494Canviada Flue gas connection | A | — | |
| 49 | EF021654Canviada Nominal duct diameter, flue | N | mm | — |
| 50 | EF020510Canviada Condensate connection | A | — | |
| 51 | EF023927Canviada Nominal diameter condensate | A | — | |
| 52 | EF020511Canviada Outer pipe diameter condensate | N | mm | — |
| 53 | EF016994Nova Seasonal space heating energy efficiency class according to 811/2013/EU | A | — | |
| 54 | EF019247Nova ηs, h (seasonal space heating energy efficiency) | N | % | — |
| 55 | EF010910Canviada Useful heat emission at nom. heat emission, operation at high temperature (P4) | N | kW | — |
| 56 | EF010911Canviada Useful efficiency at nominal heat emission, operation at high temperature (n4) | N | % | — |
| 57 | EF010897Canviada Supplementary electricity consumption at full load (ELmax) | N | kW | — |
| 58 | EF010912Canviada Supplementary electricity consumption in standby-mode (Psb) | N | kW | — |
| 59 | EF010913Canviada Standby heat loss (Pstby) | N | kW | — |
| 17 | EF020090Esborrada Max. gas pre-pressure | N | mbar | — |
| 18 | EF020541Esborrada Min. gas pre-pressure | N | mbar | — |
| 19 | EF021378Esborrada Max. oil pressure | N | mbar | — |
| 20 | EF021377Esborrada Min. oil pressure | N | mbar | — |
| 33 | EF020449Esborrada Max. operating pressure | N | bar | — |
| 34 | EF020088Esborrada Min. operating pressure | N | bar | — |
| 56 | EF010772Esborrada SEER (Seasonal Energy Efficiency Ratio) at average conditions | N | — | — |
| 57 | EF010773Esborrada SEER (Seasonal Energy Efficiency Ratio) at colder conditions | N | — | — |
| 58 | EF010774Esborrada SEER (Seasonal Energy Efficiency Ratio) at warmer conditions | N | — | — |
| 59 | EF010599Esborrada ηwh (water heating energy efficiency) | N | % | — |
| 60 | EF010777Esborrada Capacity profile | A | — | |
| 61 | EF000758Esborrada Energy efficiency class | A | — |