EC010595 versió 8
Solar heater tank with integrated central heating
- Publicada a
- ETIM-10.0
- També s'anomena
- Solar heater tank with integrated CH
Diferències de la versió 8 amb l'anterior, segons els codis de canvi que publica ETIM. La classe hi consta com a Canviada: 7 features noves, 64 canviades, 8 tretes i 30 canvis en valors permesos.
| # | Feature | Tipus | Unitat | Valors permesos |
|---|---|---|---|---|
| 6 | EF018616Nova Nominal load | R | kW | — |
| 7 | EF020006Canviada Heating capacity adjustable | L | — | — |
| 8 | EF023845Canviada Pilot light | L | — | — |
| 9 | EF016810Canviada Suitable for low-calorific natural gas | A | — | |
| 10 | EF016811Canviada Suitable for high-calorific natural gas | A | — | |
| 11 | EF016812Canviada Suitable for propane | A | — | |
| 12 | EF016813Canviada Suitable for butane | A | — | |
| 13 | EF016814Canviada Suitable for methane | A | — | |
| 14 | EF016815Canviada Suitable for liquefied petroleum gas (LPG) | A | — | |
| 15 | EF016823Canviada Suitable for hydrogen | A | — | |
| 16 | EF016800Canviada Max. percentage of hydrogen blending with natural gas | N | % | — |
| 17 | EF023847Canviada Control signal on/off | L | — | — |
| 18 | EF023848Canviada Control signal high/low | L | — | — |
| 19 | EF023850Canviada Control signal OpenTherm | L | — | — |
| 20 | EF023849Canviada Control signal 0-10 V | L | — | — |
| 21 | EF022183Canviada Burner controller high/low | L | — | — |
| 22 | EF022184Canviada Modulating burner control | L | — | — |
| 23 | EF020448Canviada Max. supply temperature (operating temperature) | N | °C | — |
| 24 | EF020089Canviada Min. return temperature | N | °C | — |
| 25 | EF025498Nova Operating pressure | R | bar | — |
| 26 | EF022931Canviada Efficiency | N | % | — |
| 27 | EF018617Nova Gas pre-pressure | R | mbar | — |
| 28 | EF020098Canviada Water-side resistance at dT 20 °C | N | kPa | — |
| 29 | EF023846Canviada Second return connection | L | — | — |
| 30 | EF020092Canviada Hot tap water capacity at 60 °C | N | l/min | — |
| 31 | EF020034Canviada Tap threshold | N | l/min | — |
| 32 | EF023890Canviada Hot tap water storage | N | l | — |
| 33 | EF000104Canviada Supply voltage | N | V | — |
| 34 | EF002225Canviada With fill- and drain valve | L | — | — |
| 35 | EF021142Canviada With pump circuit | L | — | — |
| 36 | EF002223Canviada With pressure gauge | L | — | — |
| 37 | EF021143Canviada With weather-dependent controller | L | — | — |
| 38 | EF021114Canviada With pressure expansion vessel | L | — | — |
| 39 | EF020451Canviada Built-in pressure relief valve | L | — | — |
| 40 | EF000040Canviada Height | N | mm | — |
| 41 | EF000008Canviada Width | N | mm | — |
| 42 | EF000049Canviada Depth | N | mm | — |
| 43 | EF002286Canviada Connection supply | A | — | |
| 44 | EF023886Canviada Nominal diameter of supply | A | — | |
| 45 | EF020469Canviada Outer pipe diameter supply | N | mm | — |
| 46 | EF002287Canviada Connection return | A | — | |
| 47 | EF023887Canviada Nominal diameter return | A | — | |
| 48 | EF020475Canviada Outer pipe diameter return | N | mm | — |
| 49 | EF020481Canviada Fuel connection | A | — | |
| 50 | EF023888Canviada Nominal diameter fuel | A | — | |
| 51 | EF020482Canviada Outer pipe diameter fuel | N | mm | — |
| 52 | EF020488Canviada Air supply connection | A | — | |
| 53 | EF020489Canviada Nominal duct width, air supply | N | mm | — |
| 54 | EF020494Canviada Flue gas connection | A | — | |
| 55 | EF021654Canviada Nominal duct diameter, flue | N | mm | — |
| 56 | EF021386Canviada Cold tap water connection | A | — | |
| 57 | EF020013Canviada Nominal diameter cold tap water | A | — | |
| 58 | EF020499Canviada Outer pipe diameter cold tap water | N | mm | — |
| 59 | EF021387Canviada Hot tap water connection | A | — | |
| 60 | EF010896Canviada Nominal diameter hot tap water | A | — | |
| 61 | EF020504Canviada Outer pipe diameter hot tap water | N | mm | — |
| 62 | EF020510Canviada Condensate connection | A | — | |
| 63 | EF020511Canviada Outer pipe diameter condensate | N | mm | — |
| 64 | EF002153Canviada Material boiler tank | A | — | |
| 65 | EF021064Canviada Surface protection tank | A | — | |
| 66 | EF023942Canviada Tap water boiler volume | N | l | — |
| 67 | EF023944Canviada Tap water in stock | L | — | — |
| 68 | EF023943Canviada Collector water in stock | L | — | — |
| 69 | EF023945Canviada With integrated return vessel | L | — | — |
| 70 | EF022504Canviada Assembled | L | — | — |
| 71 | EF016994Nova Seasonal space heating energy efficiency class according to 811/2013/EU | A | — | |
| 72 | EF019247Nova ηs, h (seasonal space heating energy efficiency) | N | % | — |
| 73 | EF016995Nova Water heating energy efficiency class according to 811/2013/EU | A | — | |
| 74 | EF010599Nova ηwh (water heating energy efficiency) | N | % | — |
| 75 | EF010596Canviada Standing loss (S) | N | W | — |
| 78 | CW label | N | — | — |
| 6 | EF020087Esborrada Nominal load upper value | N | kW | — |
| 7 | EF020086Esborrada Nominal load lower value | N | kW | — |
| 26 | EF020449Esborrada Max. operating pressure | N | bar | — |
| 27 | EF020088Esborrada Min. operating pressure | N | bar | — |
| 29 | EF020090Esborrada Max. gas pre-pressure | N | mbar | — |
| 30 | EF020541Esborrada Min. gas pre-pressure | N | mbar | — |
| 75 | EF010597Esborrada Seasonal space heating energy efficiency (Ns) | N | % | — |
| 78 | EF000758Esborrada Energy efficiency class | A | — |